Skip to main contentOpenAxia
CompareFor manufacturers

Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm vs Wistar motor WSME60 · 100 Nm · 12 rpm

Rated power input — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: 365 W [3; 2026-10-01]; Wistar motor WSME60 · 100 Nm · 12 rpm: 410 W [2; 2026-10-01].

Rated current — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: 1.65 A [3; 2026-10-01]; Wistar motor WSME60 · 100 Nm · 12 rpm: 1.79 A [2; 2026-10-01].

Overall length — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: 798 mm [3; 2026-10-01]; Wistar motor WSME60 · 100 Nm · 12 rpm: 830 mm [2; 2026-10-01].

Last verified: 2026-10-05

When to choose Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm

When to choose Wistar motor WSME60 · 100 Nm · 12 rpm

Verifiable indicators

Short-time duty (S2) — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: 4 min [3; 2026-10-01]; Wistar motor WSME60 · 100 Nm · 12 rpm: 4 min [2; 2026-10-01].

Rated life — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: Not published. Wistar motor WSME60 · 100 Nm · 12 rpm: Not published.

Thermal protection — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: Not published. Wistar motor WSME60 · 100 Nm · 12 rpm: Not published.

IP rating — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: IP44 [3; 2026-10-01]; Wistar motor WSME60 · 100 Nm · 12 rpm: IP44 [2; 2026-10-01].

Comparison table
PropertyGeiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpmGeiger AntriebstechnikGB59MR-100/12Wistar motor WSME60 · 100 Nm · 12 rpmWistar motorWSME60-100/12
Series & variant axes
SeriesDiffers: POWER.TECline SpindleRadio NHK vs WSME60POWER.TECline SpindleRadio NHKWSME60
Electrical
Rated voltage230 V [3; 2026-10-01]230 V [2; 2026-10-01]
Mains frequency50 Hz [3; 2026-10-01]50 Hz [2; 2026-10-01]
Power supply typeAC mains [3; 2026-10-01]AC mains [2; 2026-10-01]
Supply rating (as stated)230 V~/50 Hz [1; 2026-09-23]Not published
Rated power inputDiffers: 365 W [3; 2026-10-01] vs 410 W [2; 2026-10-01]365 W [3; 2026-10-01]410 W [2; 2026-10-01]
Rated currentDiffers: 1.65 A [3; 2026-10-01] vs 1.79 A [2; 2026-10-01]1.65 A [3; 2026-10-01]1.79 A [2; 2026-10-01]
Power factor (cos φ)> 0.95 [3; 2026-10-01]Not published
Inrush current factor1.2 x [3; 2026-10-01]Not published
Cable connectionFixed cable [1; 2026-10-01]Not published
Drive performance
Rated torque100 Nm [3; 2026-10-01]100 Nm [2; 2026-10-01]
Rated speed12 rpm [3; 2026-10-01]12 rpm [2; 2026-10-01]
Short-time duty (S2)4 min [3; 2026-10-01]4 min [2; 2026-10-01]
Duty typeS2 [3; 2026-10-01]Not published
Dimensions & mounting
Motor diameter59 mm [3; 2026-10-01]59 mm [2; 2026-10-01]
Overall lengthDiffers: 798 mm [3; 2026-10-01] vs 830 mm [2; 2026-10-01]798 mm [3; 2026-10-01]830 mm [2; 2026-10-01]
WeightDifferent basis: ≈ 6.5 kg [3; 2026-10-01] vs 6.15 kg [2; 2026-10-01]≈ 6.5 kg [3; 2026-10-01]Different basis6.15 kg [2; 2026-10-01]Different basis
Limits & protection
Limit settingMechanical [1; 2026-10-01]Mechanical [2; 2026-10-01]
Limit rangeDiffers: 24 turns [3; 2026-10-01] vs 27 turns [2; 2026-10-01]24 turns [3; 2026-10-01]27 turns [2; 2026-10-01]
Obstacle detectionNo [1; 2026-10-01]Not published
Control & communication
Control protocolProprietary RF [1; 2026-10-05]Not published
Radio frequency433 MHz [3; 2026-10-01]Not published
Two-way feedbackNo [1; 2026-10-05]Not published
Environment & protection
IP ratingIP44 [3; 2026-10-01]IP44 [2; 2026-10-01]
Noise level48 dB(A) [3; 2026-10-01]Not published
Application
ApplicationsAwning [1; 2026-10-01], Roller shutter [1; 2026-10-01]Not published
DocumentsRequest datasheetRequest datasheet

Relations and interchangeability

Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm → Wistar motor WSME60 · 100 Nm · 12 rpm

Not directly interchangeable

OpenAxia comparison of published specifications — not a manufacturer statement [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik manufacturer site (product catalog); 2026-10-05] [Geiger Antriebstechnik manufacturer site (product catalog); 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01]

  • Same product type (tubular motor)
  • Ø59 mm (same class)
  • Torque 100 Nm (same)
  • Speed 12 rpm (same)
  • 230 V (same)
  • Power supply AC mains (same)
  • Mains 50 Hz (same)
  • Limits: Mechanical (same)
  • Limit turns 27
  • Protection IP44
  • Control system not confirmed
  • 32 mm longer: check the space between brackets
  • Other brand: crown & drive adapters, head and bracket must be checked

Required changes / checks: Control system not confirmed; 32 mm longer: check the space between brackets; Other brand: crown & drive adapters, head and bracket must be checked

Not checked: crown & drive adapters and motor head; Not checked: brackets; Not checked: remote pairing; Not checked: wiring

Wistar motor WSME60 · 100 Nm · 12 rpm → Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm

Not directly interchangeable

OpenAxia comparison of published specifications — not a manufacturer statement [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Wistar motor manufacturer site (product catalog); 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik manufacturer site (product catalog); 2026-10-05] [Geiger Antriebstechnik manufacturer site (product catalog); 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik PDF catalogue GEIGER_Katalog_04_TECLINE_100W9004_DE.pdf; 2026-10-01] [Geiger Antriebstechnik manufacturer site (product catalog); 2026-10-01]

  • Same product type (tubular motor)
  • Ø59 mm (same class)
  • Torque 100 Nm (same)
  • Speed 12 rpm (same)
  • 230 V (same)
  • Power supply AC mains (same)
  • Mains 50 Hz (same)
  • Limits: Mechanical (same)
  • Length 798 mm
  • Protection IP44
  • Control system not confirmed
  • Fewer limit turns (24 vs 27): check your shutter drop
  • Other brand: crown & drive adapters, head and bracket must be checked

Required changes / checks: Control system not confirmed; Fewer limit turns (24 vs 27): check your shutter drop; Other brand: crown & drive adapters, head and bracket must be checked

Not checked: crown & drive adapters and motor head; Not checked: brackets; Not checked: remote pairing; Not checked: wiring

Series

Questions and answers

What supply voltage and frequency does each use?
Rated voltage — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: 230 V; Wistar motor WSME60 · 100 Nm · 12 rpm: 230 V. Mains frequency — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: 50 Hz; Wistar motor WSME60 · 100 Nm · 12 rpm: 50 Hz. Power supply type — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: AC mains; Wistar motor WSME60 · 100 Nm · 12 rpm: AC mains.
Which tube diameters do they fit?
Motor diameter — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: 59 mm; Wistar motor WSME60 · 100 Nm · 12 rpm: 59 mm.
What torque and speed is each rated for?
Rated torque — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: 100 Nm; Wistar motor WSME60 · 100 Nm · 12 rpm: 100 Nm. Rated speed — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: 12 rpm; Wistar motor WSME60 · 100 Nm · 12 rpm: 12 rpm.
What protocols and control options does each support?
Limit setting — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: Mechanical; Wistar motor WSME60 · 100 Nm · 12 rpm: Mechanical. Control protocol — Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm: Proprietary RF.

Sources

  1. ↑Geiger Antriebstechnik manufacturer site (product catalog)geiger.deSeries / product line: POWER.TECline SpindleRadio NHKManufacturer-stated · Observed 2026-10-01 · Retrieved 2026-09-23 · Public web pageUsed for: 8234, 1447, 8239, 8238, 8237, 49513, 49514, 8236, 8235
  2. ↑Wistar motor manufacturer site (product catalog)wistarmotor.comSeries / product line: Ref: WSME60Manufacturer-stated · Observed 2026-10-01 · Retrieved 2026-10-01 · Public web pageUsed for: 12586, 12572, 12584, 12562, 12570, 12574, 12558, 12560, 12576, 12566, 12578, 12582, 12588, 12580, 12564
  3. ↑Geiger Antriebstechnik PDF cataloguegeiger.deRated voltage: Spannung: 230V~/50 Hz [GB59MR-100/12] (p. 53)Manufacturer-stated · Observed 2026-10-01 · Retrieved 2026-10-01 · Public web pageUsed for: 32599, 32602, 32600, 32610, 32604, 32606, 32608, 32612, 32614, 32622, 32624, 32627, 32620, 32631, 32616, 32629, 32618, 32626
See something wrong? Report an error