Geiger Antriebstechnik POWER.TECline SpindleRadio NHK
4 models with rated torque from 80 – 140 Nm.
Sources: 2 manufacturer documents · Last verified 2026-10-05 · How we collect data →
Overview
Variant suffixes
- NHK
- Manual override (German "Nothandkurbel"): the drive can still be moved with a hand crank if power fails.
OpenAxia glossary note — editorial explanation, not a sourced claim.
Models
| Model | Part no. | Torque | Rated speed | Series / product line | Rated voltage | Mains frequency | Power supply type | Rated power input | Rated current | Power factor (cos φ) | Inrush current factor | Cable connection | Short-time duty (S2) | Duty type | Motor diameter | Overall length | Weight | Limit setting | Limit range | Obstacle detection | Control protocol | Radio frequency | Two-way feedback | IP rating | Noise level | Applications | Rated torque | Rated speed | Compare |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 80 Nm · 12 rpm | GB59MR-80/12 | 80 Nm | 12 rpm | POWER.TECline SpindleRadio NHK | 230 V | 50 Hz | AC mains | 270 W | 1.2 A | >0.95 | 1.2 x | Fixed cable | 4 min | S2 | 59 mm | 798 mm | ≈6.5 kg | Mechanical | 24 turns | − | Proprietary RF | 433 MHz | − | IP44 | 48 dB(A) | Awning, Roller shutter | 80 Nm | 12 rpm | |
| Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 100 Nm · 12 rpm | GB59MR-100/12 | 100 Nm | 12 rpm | POWER.TECline SpindleRadio NHK | 230 V | 50 Hz | AC mains | 365 W | 1.65 A | >0.95 | 1.2 x | Fixed cable | 4 min | S2 | 59 mm | 798 mm | ≈6.5 kg | Mechanical | 24 turns | − | Proprietary RF | 433 MHz | − | IP44 | 48 dB(A) | Awning, Roller shutter | 100 Nm | 12 rpm | |
| Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 120 Nm · 9 rpm | GB59MR-120/09 | 120 Nm | 9 rpm | POWER.TECline SpindleRadio NHK | 230 V | 50 Hz | AC mains | 270 W | 1.2 A | >0.95 | 1.2 x | Fixed cable | 4 min | S2 | 59 mm | 843 mm | ≈6.5 kg | Mechanical | 24 turns | − | Proprietary RF | 433 MHz | − | IP44 | 48 dB(A) | Awning, Roller shutter | 120 Nm | 9 rpm | |
| Geiger Antriebstechnik POWER.TECline SpindleRadio NHK · 140 Nm · 9 rpm | GB59MR-140/09 | 140 Nm | 9 rpm | POWER.TECline SpindleRadio NHK | 230 V | 50 Hz | AC mains | 365 W | 1.65 A | >0.95 | 1.2 x | Fixed cable | 4 min | S2 | 59 mm | 843 mm | ≈6.5 kg | Mechanical | 24 turns | − | Proprietary RF | 433 MHz | − | IP44 | 48 dB(A) | Awning, Roller shutter | 140 Nm | 9 rpm |
| Torque × Rated speed | 9 rpm | 12 rpm |
|---|---|---|
| 80 Nm | Not in OpenAxia catalog | GB59MR-80/12 |
| 100 Nm | Not in OpenAxia catalog | GB59MR-100/12 |
| 120 Nm | GB59MR-120/09 | Not in OpenAxia catalog |
| 140 Nm | GB59MR-140/09 | Not in OpenAxia catalog |
Show all 4 model links
Missing a variant or part number? Manufacturers can update this series.
Source: Geiger Antriebstechnik PDF catalogue (Manufacturer-stated), Geiger Antriebstechnik manufacturer site (Manufacturer-stated). Last checked 2026-10-05. All sources (2) · Learn more about this data
Sources
- ↑Geiger Antriebstechnik PDF cataloguegeiger.deRated torque: Drehmoment: 80 Nm [GB59MR-80/12] (p. 53)Used for: GB59MR-80/12 rated torque, GB59MR-140/09 rated torque, GB59MR-80/12 rated voltage, GB59MR-100/12 rated voltage, GB59MR-120/09 rated voltage, GB59MR-140/09 rated voltage, GB59MR-80/12 rated power input, GB59MR-100/12 rated power input, GB59MR-120/09 rated power input, GB59MR-140/09 rated power input, GB59MR-80/12 rated current, GB59MR-100/12 rated current, GB59MR-120/09 rated current, GB59MR-140/09 rated current, GB59MR-80/12 power factor (cos φ), GB59MR-100/12 power factor (cos φ), GB59MR-120/09 power factor (cos φ), GB59MR-140/09 power factor (cos φ), GB59MR-80/12 inrush current factor, GB59MR-100/12 inrush current factor, GB59MR-120/09 inrush current factor, GB59MR-140/09 inrush current factor, GB59MR-80/12 short-time duty (s2), GB59MR-100/12 short-time duty (s2), GB59MR-120/09 short-time duty (s2), GB59MR-140/09 short-time duty (s2), GB59MR-80/12 duty type, GB59MR-100/12 duty type, GB59MR-120/09 duty type, GB59MR-140/09 duty type, GB59MR-80/12 motor diameter, GB59MR-100/12 motor diameter, GB59MR-120/09 motor diameter, GB59MR-140/09 motor diameter, GB59MR-80/12 overall length, GB59MR-100/12 overall length, GB59MR-80/12 limit range, GB59MR-100/12 limit range, GB59MR-120/09 limit range, GB59MR-140/09 limit range, GB59MR-80/12 ip rating, GB59MR-100/12 ip rating, GB59MR-120/09 ip rating, GB59MR-140/09 ip rating, GB59MR-80/12 noise level, GB59MR-100/12 noise level, GB59MR-120/09 noise level, GB59MR-140/09 noise level, GB59MR-100/12 rated torque, GB59MR-120/09 rated torque, GB59MR-80/12 rated speed, GB59MR-100/12 rated speed, GB59MR-120/09 rated speed, GB59MR-140/09 rated speed
- ↑Geiger Antriebstechnik manufacturer site (product catalog)geiger.dePart number: GB59MR-80/12Used for: GB59MR-80/12 part no., GB59MR-100/12 part no., GB59MR-120/09 part no., GB59MR-140/09 part no., GB59MR-80/12 series / product line, GB59MR-100/12 series / product line, GB59MR-120/09 series / product line, GB59MR-140/09 series / product line, GB59MR-80/12 cable connection, GB59MR-100/12 cable connection, GB59MR-120/09 cable connection, GB59MR-140/09 cable connection, GB59MR-80/12 limit setting, GB59MR-100/12 limit setting, GB59MR-120/09 limit setting, GB59MR-140/09 limit setting, GB59MR-80/12 obstacle detection, GB59MR-100/12 obstacle detection, GB59MR-120/09 obstacle detection, GB59MR-140/09 obstacle detection, GB59MR-80/12 two-way feedback, GB59MR-100/12 two-way feedback, GB59MR-120/09 two-way feedback, GB59MR-140/09 two-way feedback