Skip to main contentOpenAxia
CompareFor manufacturers

Somfy Sonesse ULTRA 50

by Somfy

7 models with rated torque from 4 – 6 Nm.

Lowest 4 Nm Highest 6 Nm

Sources: 6 manufacturer documents · Last verified 2026-10-06 · How we collect data →

Overview

Variant suffixes

RTS
Somfy's one-way radio control system (433.42 MHz): the motor receives commands but does not report its position back.
RS-485
Wired RS-485 serial control interface.
DC
Low-voltage DC supply variant (for example a battery, solar panel or DC power supply).

OpenAxia glossary note — editorial explanation, not a sourced claim.

Models

Models in this series
ModelPart no.Control protocolPower supplySeries / product lineLifecycle status (manufacturer)Replaces part numberMarket variantRated voltageSupply voltage (min)Supply voltage (max)Mains frequencyRated power inputStandby powerRated currentPower factor (cos φ)Inrush current factorProtection class (electrical)Cable connectionCable typeCable lengthRated torquePeak torqueRated speedSpeed range (max)Short-time duty (S2)Duty typeMax loadRated lifeMotor diameterFits tube diameterOverall lengthWeightCompatible tube profilesMotor head typeMounting sideMax shade widthLimit settingLimit rangeIntermediate positionsObstacle detectionManual overrideSoft start / soft stopThermal protectionNoiseless soft brakeControl protocolRadio frequencyModulationRadio rangeTwo-way feedbackMax paired transmittersWired inputsWorks withSensor inputsTimer / astroIP ratingOperating temp. (min)Operating temp. (max)Noise levelAmbient humidityStorage temp. (min)Storage temp. (max)ApplicationsMarks stated by vendorCarbon footprint (PEP/EPD)Compare
Somfy Sonesse® ULTRA 504 A8 DC RS4851134022RS-485DC————24 V———36 W0.48 W1.5 A—————0.25 m4 Nm—25 rpm—5 min———————————Electronic38 turns——————RS-485—————————IP200 °C60 °C38 dB(A)——————
Somfy Sonesse® ULTRA 504 A8 DC RTS1134023RTSDC————24 V———36 W0.48 W1.5 A—————0.25 m4 Nm—25 rpm—5 min———————————Electronic38 turns——————RTS433.42 MHz—200 m——————IP200 °C60 °C38 dB(A)——————
Somfy Sonesse ULTRA 50 Sonesse® ULTRA 506A21002558—AC mains————120 V——60 Hz114 W0 W0.95 A—————3 m6 Nm—24 rpm—4 min————————————46 turns————————————————IP310 °C60 °C38 dB(A)——————
Somfy Sonesse ULTRA 50 Sonesse® ULTRA 506A2 RH1002560—AC mains————120 V——60 Hz114 W0 W0.95 A—————3 m6 Nm—24 rpm—4 min————————————46 turns————————————————IP310 °C60 °C38 dB(A)——————
Somfy Sonesse® ULTRA 506A2 RS4851002566RS-485AC mains————120 V——60 Hz114 W0.5 W0.95 A—————3 m6 Nm—24 rpm—4 min———————————Electronic300 turns——————RS-485—————————IP310 °C60 °C38 dB(A)——————
Somfy Sonesse ULTRA 50 Sonesse® ULTRA 506A2 RTS1002562RTSAC mains————120 V——60 Hz114 W0.5 W0.95 A—————3 m6 Nm—24 rpm—4 min———————————Electronic250 turns——————RTS433.42 MHz————————IP310 °C60 °C38 dB(A)——————
Somfy Sonesse® ULTRA 506A2 RTS RH1002564RTSAC mains————120 V——60 Hz114 W0.5 W0.95 A—————3 m6 Nm—24 rpm—4 min———————————Electronic250 turns——————RTS433.42 MHz————————IP310 °C60 °C38 dB(A)——————

— means no value: the manufacturer does not publish it, it does not apply to this product type, or there is none on record. Value states

Missing a variant or part number? Manufacturers can update this series.

Source: manufacturer documents (6). Last checked 2026-10-06. All sources (6) · Learn more about this data

Sources

  1. ↑Somfy PDF catalogueservice.somfy.comRated torque: Torque: 4 Nm [1134022] (p. 1)Manufacturer-stated · Observed 2026-10-06 · Retrieved 2026-10-06 · Public web pageUsed for: Sonesse® ULTRA 504 A8 DC RS485 rated torque, Sonesse® ULTRA 504 A8 DC RS485 rated voltage, Sonesse® ULTRA 504 A8 DC RS485 rated current, Sonesse® ULTRA 504 A8 DC RS485 cable length, Sonesse® ULTRA 504 A8 DC RS485 rated speed, Sonesse® ULTRA 504 A8 DC RS485 short-time duty (s2), Sonesse® ULTRA 504 A8 DC RS485 limit setting, Sonesse® ULTRA 504 A8 DC RS485 limit range, Sonesse® ULTRA 504 A8 DC RS485 ip rating, Sonesse® ULTRA 504 A8 DC RS485 operating temp. (min), Sonesse® ULTRA 504 A8 DC RS485 operating temp. (max)
  2. ↑Somfy PDF catalogueservice.somfy.comRated torque: Torque: 6 Nm [1002564] (p. 1)Manufacturer-stated · Observed 2026-10-06 · Retrieved 2026-10-06 · Public web pageUsed for: Sonesse® ULTRA 506A2 RTS RH rated torque, Sonesse® ULTRA 506A2 RTS rated voltage, Sonesse® ULTRA 506A2 RTS RH rated voltage, Sonesse® ULTRA 506A2 RTS rated current, Sonesse® ULTRA 506A2 RTS RH rated current, Sonesse® ULTRA 506A2 RTS cable length, Sonesse® ULTRA 506A2 RTS RH cable length, Sonesse® ULTRA 506A2 RTS rated torque, Sonesse® ULTRA 506A2 RTS rated speed, Sonesse® ULTRA 506A2 RTS RH rated speed, Sonesse® ULTRA 506A2 RTS short-time duty (s2), Sonesse® ULTRA 506A2 RTS RH short-time duty (s2), Sonesse® ULTRA 506A2 RTS limit setting, Sonesse® ULTRA 506A2 RTS RH limit setting, Sonesse® ULTRA 506A2 RTS limit range, Sonesse® ULTRA 506A2 RTS RH limit range, Sonesse® ULTRA 506A2 RTS ip rating, Sonesse® ULTRA 506A2 RTS RH ip rating, Sonesse® ULTRA 506A2 RTS operating temp. (min), Sonesse® ULTRA 506A2 RTS RH operating temp. (min), Sonesse® ULTRA 506A2 RTS operating temp. (max), Sonesse® ULTRA 506A2 RTS RH operating temp. (max), Sonesse® ULTRA 506A2 RTS noise level, Sonesse® ULTRA 506A2 RTS RH noise level
  3. ↑Somfy Systems (North America) manufacturer site (product catalog)somfysystems.comPart number: Ref. : 1134022Manufacturer-stated · Observed 2026-09-30 · Retrieved 2026-09-30 · Public web pageUsed for: Sonesse® ULTRA 504 A8 DC RS485 part no., Sonesse® ULTRA 504 A8 DC RTS part no., Sonesse® ULTRA 506A2 part no., Sonesse® ULTRA 506A2 RH part no., Sonesse® ULTRA 506A2 RS485 part no., Sonesse® ULTRA 506A2 RTS part no., Sonesse® ULTRA 506A2 RTS RH part no., Sonesse® ULTRA 504 A8 DC RS485 rated power input, Sonesse® ULTRA 504 A8 DC RTS rated power input, Sonesse® ULTRA 506A2 rated power input, Sonesse® ULTRA 506A2 RH rated power input, Sonesse® ULTRA 506A2 RS485 rated power input, Sonesse® ULTRA 506A2 RTS rated power input, Sonesse® ULTRA 506A2 RTS RH rated power input, Sonesse® ULTRA 504 A8 DC RS485 standby power, Sonesse® ULTRA 504 A8 DC RTS standby power, Sonesse® ULTRA 506A2 standby power, Sonesse® ULTRA 506A2 RH standby power, Sonesse® ULTRA 506A2 RS485 standby power, Sonesse® ULTRA 506A2 RTS standby power, Sonesse® ULTRA 506A2 RTS RH standby power, Sonesse® ULTRA 504 A8 DC RTS radio range
  4. ↑Somfy PDF catalogueservice.somfy.comRated voltage: Voltage Supply: 24V DC [1134023] (p. 6)Manufacturer-stated · Observed 2026-10-06 · Retrieved 2026-10-06 · Public web pageUsed for: Sonesse® ULTRA 504 A8 DC RTS rated voltage, Sonesse® ULTRA 504 A8 DC RTS rated current, Sonesse® ULTRA 504 A8 DC RTS cable length, Sonesse® ULTRA 504 A8 DC RTS rated torque, Sonesse® ULTRA 504 A8 DC RTS rated speed, Sonesse® ULTRA 504 A8 DC RTS short-time duty (s2), Sonesse® ULTRA 504 A8 DC RTS limit setting, Sonesse® ULTRA 504 A8 DC RTS limit range, Sonesse® ULTRA 504 A8 DC RTS ip rating, Sonesse® ULTRA 504 A8 DC RTS operating temp. (min), Sonesse® ULTRA 504 A8 DC RTS operating temp. (max)
  5. ↑Somfy PDF catalogueservice.somfy.comRated voltage: Voltage Supply: 120V AC, 60Hz [1002558] (p. 1)Manufacturer-stated · Observed 2026-10-06 · Retrieved 2026-10-06 · Public web pageUsed for: Sonesse® ULTRA 506A2 rated voltage, Sonesse® ULTRA 506A2 RH rated voltage, Sonesse® ULTRA 506A2 rated current, Sonesse® ULTRA 506A2 RH rated current, Sonesse® ULTRA 506A2 cable length, Sonesse® ULTRA 506A2 RH cable length, Sonesse® ULTRA 506A2 rated torque, Sonesse® ULTRA 506A2 RH rated torque, Sonesse® ULTRA 506A2 rated speed, Sonesse® ULTRA 506A2 RH rated speed, Sonesse® ULTRA 506A2 short-time duty (s2), Sonesse® ULTRA 506A2 RH short-time duty (s2), Sonesse® ULTRA 506A2 limit range, Sonesse® ULTRA 506A2 RH limit range, Sonesse® ULTRA 506A2 ip rating, Sonesse® ULTRA 506A2 RH ip rating, Sonesse® ULTRA 506A2 operating temp. (min), Sonesse® ULTRA 506A2 RH operating temp. (min), Sonesse® ULTRA 506A2 operating temp. (max), Sonesse® ULTRA 506A2 RH operating temp. (max), Sonesse® ULTRA 506A2 noise level, Sonesse® ULTRA 506A2 RH noise level
  6. ↑Somfy PDF catalogueservice.somfy.comRated voltage: Voltage Supply: 120V AC, 60Hz [1002566] (p. 1)Manufacturer-stated · Observed 2026-10-06 · Retrieved 2026-10-06 · Public web pageUsed for: Sonesse® ULTRA 506A2 RS485 rated voltage, Sonesse® ULTRA 506A2 RS485 rated current, Sonesse® ULTRA 506A2 RS485 cable length, Sonesse® ULTRA 506A2 RS485 rated torque, Sonesse® ULTRA 506A2 RS485 rated speed, Sonesse® ULTRA 506A2 RS485 short-time duty (s2), Sonesse® ULTRA 506A2 RS485 limit setting, Sonesse® ULTRA 506A2 RS485 limit range, Sonesse® ULTRA 506A2 RS485 ip rating, Sonesse® ULTRA 506A2 RS485 operating temp. (min), Sonesse® ULTRA 506A2 RS485 operating temp. (max), Sonesse® ULTRA 506A2 RS485 noise level

Take the next step

Compare sizes side by side, or look across brands.

See something wrong? Report an error