Skip to main contentOpenAxia
CompareFor manufacturers

Somfy Sonesse 50

by Somfy

14 models with rated torque from 6 – 10 Nm.

Lowest 6 Nm Highest 10 Nm

Sources: 2 manufacturer documents · Last verified 2026-10-29 · How we collect data →

Overview

Variant suffixes

RTS
Somfy's one-way radio control system (433.42 MHz): the motor receives commands but does not report its position back.
RS-485
Wired RS-485 serial control interface.

OpenAxia glossary note — editorial explanation, not a sourced claim.

Models

Models in this series
ModelPart no.Control protocolPower supplyRated voltageMains frequencyRated power inputStandby powerRated currentCable lengthRated torqueRated speedShort-time duty (S2)Limit settingLimit rangeControl protocolRadio frequencyRadio rangeIP ratingOperating temp. (min)Operating temp. (max)Noise levelCompare
Somfy Sonesse 50 Sonesse® 506S2 RS4851002286RS-485AC mains120 V60 Hz140 W0.5 W1.2 A3 m6 Nm32 rpm4 minElectronic300 turnsRS-485——IP44-20 °C70 °C45 dB(A)
Somfy Sonesse 50 Sonesse® 510S2 RS4851002287RS-485AC mains120 V60 Hz200 W0.5 W1.66 A3 m10 Nm32 rpm4 minElectronic300 turnsRS-485——IP44-20 °C70 °C47 dB(A)
Somfy Sonesse 50 10018001001800—AC mains120 V—146 W0 W——————————IP44——45 dB(A)
Somfy Sonesse 50 10023241002324—AC mains120 V—200 W0 W——————————IP44——47.2 dB(A)
Somfy Sonesse 50 Sonesse® 506S21001814—AC mains120 V—140 W0 W——————————IP44——45 dB(A)
Somfy Sonesse 50 Sonesse® 506S2 PA1001801—AC mains120 V—146 W0 W——————————IP44——45 dB(A)
Somfy Sonesse 50 Sonesse® 506S2 RH1001812—AC mains120 V—140 W0 W——————————IP44——45 dB(A)
Somfy Sonesse 50 Sonesse® 506S2 RTS1001809RTSAC mains120 V—140 W0.5 W———————RTS433.42 MHz200 mIP44——45.1 dB(A)
Somfy Sonesse 50 Sonesse® 506S2 RTS RH1001806RTSAC mains120 V—140 W0.5 W———————RTS433.42 MHz50 mIP44——45.1 dB(A)
Somfy Sonesse 50 Sonesse® 510S21001813—AC mains120 V—200 W0 W——————————IP44——47.2 dB(A)
Somfy Sonesse 50 Sonesse® 510S2 PA1002323—AC mains120 V—200 W0 W——————————IP44——47.2 dB(A)
Somfy Sonesse 50 Sonesse® 510S2 RH1001810—AC mains120 V—200 W0 W——————————IP44——47.2 dB(A)
Somfy Sonesse 50 Sonesse® 510S2 RTS1001807RTSAC mains120 V—200 W0.5 W———————RTS433.42 MHz50 mIP44——47.2 dB(A)
Somfy Sonesse 50 Sonesse® 510S2 RTS RH1001805RTSAC mains120 V—200 W0.5 W———————RTS433.42 MHz50 mIP44——47.2 dB(A)

— means no value: the manufacturer does not publish it, it does not apply to this product type, or there is none on record. Value states

Control protocol × Power supply
Control protocol × Power supplyAC mains
RS-485Sonesse® 506S2 RS485, Sonesse® 510S2 RS485
RTSSonesse® 506S2 RTS, Sonesse® 506S2 RTS RH, Sonesse® 510S2 RTS, Sonesse® 510S2 RTS RH

Missing a variant or part number? Manufacturers can update this series.

Source: Somfy PDF catalogue (Manufacturer-stated), Somfy Systems (North America) manufacturer site (Manufacturer-stated). Last checked 2026-10-29. All sources (2) · Learn more about this data

Sources

  1. ↑Somfy PDF catalogueservice.somfy.comRated torque: Torque: 6 Nm [1002286] (p. 1)Manufacturer-stated · Observed 2026-10-06 · Retrieved 2026-10-06 · Public web pageUsed for: Sonesse® 506S2 RS485 rated torque, Sonesse® 510S2 RS485 rated torque, Sonesse® 506S2 RS485 rated voltage, Sonesse® 510S2 RS485 rated voltage, Sonesse® 506S2 RS485 rated current, Sonesse® 510S2 RS485 rated current, Sonesse® 506S2 RS485 cable length, Sonesse® 510S2 RS485 cable length, Sonesse® 506S2 RS485 rated speed, Sonesse® 510S2 RS485 rated speed, Sonesse® 506S2 RS485 short-time duty (s2), Sonesse® 510S2 RS485 short-time duty (s2), Sonesse® 506S2 RS485 limit setting, Sonesse® 510S2 RS485 limit setting, Sonesse® 506S2 RS485 limit range, Sonesse® 510S2 RS485 limit range, Sonesse® 506S2 RS485 ip rating, Sonesse® 510S2 RS485 ip rating, Sonesse® 506S2 RS485 operating temp. (min), Sonesse® 510S2 RS485 operating temp. (min), Sonesse® 506S2 RS485 operating temp. (max), Sonesse® 510S2 RS485 operating temp. (max), Sonesse® 506S2 RS485 noise level
  2. ↑Somfy Systems (North America) manufacturer site (product catalog)somfysystems.comPart number: Ref. : 1002286Manufacturer-stated · Observed 2026-09-30 · Retrieved 2026-09-30 · Public web pageUsed for: Sonesse® 506S2 RS485 part no., Sonesse® 510S2 RS485 part no., Sonesse® 506S2 part no., Sonesse® 506S2 PA part no., Sonesse® 506S2 RH part no., Sonesse® 506S2 RTS part no., Sonesse® 506S2 RTS RH part no., Sonesse® 510S2 part no., Sonesse® 510S2 PA part no., Sonesse® 510S2 RH part no., Sonesse® 510S2 RTS part no., Sonesse® 510S2 RTS RH part no., 1001800 rated voltage, 1002324 rated voltage, Sonesse® 506S2 rated voltage, Sonesse® 506S2 PA rated voltage, Sonesse® 506S2 RH rated voltage, Sonesse® 506S2 RTS rated voltage, Sonesse® 506S2 RTS RH rated voltage, Sonesse® 510S2 rated voltage, Sonesse® 510S2 PA rated voltage, Sonesse® 510S2 RH rated voltage, Sonesse® 510S2 RTS rated voltage, Sonesse® 510S2 RTS RH rated voltage, Sonesse® 506S2 RS485 rated power input, Sonesse® 510S2 RS485 rated power input, 1001800 rated power input, 1002324 rated power input, Sonesse® 506S2 rated power input, Sonesse® 506S2 PA rated power input, Sonesse® 506S2 RH rated power input, Sonesse® 506S2 RTS rated power input, Sonesse® 506S2 RTS RH rated power input, Sonesse® 510S2 rated power input, Sonesse® 510S2 PA rated power input, Sonesse® 510S2 RH rated power input, Sonesse® 510S2 RTS rated power input, Sonesse® 510S2 RTS RH rated power input, Sonesse® 506S2 RS485 standby power, Sonesse® 510S2 RS485 standby power, 1001800 standby power, 1002324 standby power, Sonesse® 506S2 standby power, Sonesse® 506S2 PA standby power, Sonesse® 506S2 RH standby power, Sonesse® 506S2 RTS standby power, Sonesse® 506S2 RTS RH standby power, Sonesse® 510S2 standby power, Sonesse® 510S2 PA standby power, Sonesse® 510S2 RH standby power, Sonesse® 510S2 RTS standby power, Sonesse® 510S2 RTS RH standby power, Sonesse® 506S2 RTS radio range, Sonesse® 506S2 RTS RH radio range, Sonesse® 510S2 RTS radio range, Sonesse® 510S2 RTS RH radio range, 1001800 ip rating, 1002324 ip rating, Sonesse® 506S2 ip rating, Sonesse® 506S2 PA ip rating, Sonesse® 506S2 RH ip rating, Sonesse® 506S2 RTS ip rating, Sonesse® 506S2 RTS RH ip rating, Sonesse® 510S2 ip rating, Sonesse® 510S2 PA ip rating, Sonesse® 510S2 RH ip rating, Sonesse® 510S2 RTS ip rating, Sonesse® 510S2 RTS RH ip rating, 1001800 noise level, 1002324 noise level, Sonesse® 506S2 noise level, Sonesse® 506S2 PA noise level, Sonesse® 506S2 RH noise level, Sonesse® 506S2 RTS noise level, Sonesse® 506S2 RTS RH noise level, Sonesse® 510S2 noise level, Sonesse® 510S2 PA noise level, Sonesse® 510S2 RH noise level, Sonesse® 510S2 RTS noise level, Sonesse® 510S2 RTS RH noise level

Take the next step

Compare sizes side by side, or look across brands.

See something wrong? Report an error