Skip to main contentOpenAxia
CompareFor manufacturers

Somfy LT60

by Somfy

6 models with rated torque from 60 – 100 Nm.

Lowest 60 Nm Highest 100 Nm

Sources: 2 manufacturer documents · Last verified 2026-10-07 · How we collect data →

Models

Models in this series
ModelPart no.Power supplyTorqueSeries / product lineLifecycle status (manufacturer)Replaces part numberMarket variantRated voltageSupply voltage (min)Supply voltage (max)Mains frequencyRated power inputStandby powerRated currentPower factor (cos φ)Inrush current factorProtection class (electrical)Cable connectionCable typeCable lengthPeak torqueRated speedSpeed range (max)Short-time duty (S2)Duty typeMax loadRated lifeMotor diameterFits tube diameterOverall lengthWeightCompatible tube profilesMotor head typeMounting sideMax shade widthLimit settingLimit rangeIntermediate positionsObstacle detectionManual overrideSoft start / soft stopThermal protectionNoiseless soft brakeControl protocolRadio frequencyModulationRadio rangeTwo-way feedbackMax paired transmittersWired inputsWorks withSensor inputsTimer / astroIP ratingOperating temp. (min)Operating temp. (max)Noise levelAmbient humidityStorage temp. (min)Storage temp. (max)ApplicationsMarks stated by vendorCarbon footprint (PEP/EPD)Rated torqueCompare
Somfy LT60 660R2 60/14 SJTW1162272AC mains60 Nm————120 V———285 W0 W————————14 rpm———————————————————————————————IP44——63 dB(A)——————60 Nm
Somfy LT60 680R2 80/14 SJTW1164262AC mains80 Nm————120 V———285 W0 W————————14 rpm———————————————————————————————IP44——65 dB(A)——————80 Nm
Somfy LT60 6100R2 100/14 SJTW1166290AC mains100 Nm————120 V———430 W0 W————————14 rpm———————————————————————————————IP44——67 dB(A)——————100 Nm
Somfy LT60 6100R2 CMO1166016AC mains—————120 V——60 Hz430 W0 W———————————————————————34 turns————————————————IP44-10 °C40 °C67 dB(A)———————
Somfy LT60 660R2 CMO1162014AC mains—————120 V——60 Hz285 W0 W———————————————————————34 turns————————————————IP44-10 °C40 °C63 dB(A)———————
Somfy LT60 680R2 CMO1164013AC mains—————120 V——60 Hz285 W0 W———————————————————————34 turns————————————————IP44-10 °C40 °C65 dB(A)———————

— means no value: the manufacturer does not publish it, it does not apply to this product type, or there is none on record. Value states

Missing a variant or part number? Manufacturers can update this series.

Source: Model-name rule somfy-explicit-torque-speed-v2: Somfy model names carrying an explicit "<Nm>/<rpm>" pair, e.g. "525A2 25/20 SJTW". (Manufacturer-stated), Somfy PDF catalogue (Page 1) (Manufacturer-stated). Last checked 2026-10-07. All sources (2) · Learn more about this data

Sources

  1. ↑Model-name rule somfy-explicit-torque-speed-v2: Somfy model names carrying an explicit "<Nm>/<rpm>" pair, e.g. "525A2 25/20 SJTW".somfysystems.com660R2 60/14 SJTWManufacturer-stated · Observed 2026-10-07 · Retrieved 2026-10-07 · Public web pageUsed for: 660R2 60/14 SJTW rated torque, 6100R2 100/14 SJTW rated torque, 660R2 60/14 SJTW part no., 680R2 80/14 SJTW part no., 6100R2 100/14 SJTW part no., 6100R2 CMO part no., 660R2 CMO part no., 680R2 CMO part no., 660R2 60/14 SJTW rated voltage, 680R2 80/14 SJTW rated voltage, 6100R2 100/14 SJTW rated voltage, 660R2 60/14 SJTW rated power input, 680R2 80/14 SJTW rated power input, 6100R2 100/14 SJTW rated power input, 6100R2 CMO rated power input, 660R2 CMO rated power input, 680R2 CMO rated power input, 660R2 60/14 SJTW standby power, 680R2 80/14 SJTW standby power, 6100R2 100/14 SJTW standby power, 6100R2 CMO standby power, 660R2 CMO standby power, 680R2 CMO standby power, 660R2 60/14 SJTW rated speed, 680R2 80/14 SJTW rated speed, 6100R2 100/14 SJTW rated speed, 660R2 60/14 SJTW ip rating, 680R2 80/14 SJTW ip rating, 6100R2 100/14 SJTW ip rating, 660R2 60/14 SJTW noise level, 680R2 80/14 SJTW noise level, 6100R2 100/14 SJTW noise level, 6100R2 CMO noise level, 660R2 CMO noise level, 680R2 CMO noise level, 680R2 80/14 SJTW rated torque
  2. ↑Somfy PDF catalogue 600series_databook_11-2018.pdf (Page 1)service.somfy.comRated voltage: Voltage Supply: 120V AC, 60Hz [1166016] (p. 9)Manufacturer-stated · Observed 2026-10-06 · Retrieved 2026-10-06 · Public web pageUsed for: 6100R2 CMO rated voltage, 660R2 CMO rated voltage, 680R2 CMO rated voltage, 6100R2 CMO limit range, 660R2 CMO limit range, 680R2 CMO limit range, 6100R2 CMO ip rating, 660R2 CMO ip rating, 680R2 CMO ip rating, 6100R2 CMO operating temp. (min), 660R2 CMO operating temp. (min), 680R2 CMO operating temp. (min), 6100R2 CMO operating temp. (max), 660R2 CMO operating temp. (max), 680R2 CMO operating temp. (max)

Take the next step

Compare sizes side by side, or look across brands.

See something wrong? Report an error