Compare motors
Last verified: 2026-10-07
Verifiable indicators
Short-time duty (S2) — Becker R12-17-C01 PLUS: 4 min [3; 2026-10-03]; Becker R12-17-C12 PLUS: 4 min [3; 2026-10-03]; Nice 230 Vac E M 1517: 4 min [4; 2026-10-01]. Gaposa XQ50 SENSE · 13 Nm · 17 rpm: Not published.
Rated life — Gaposa XQ50 SENSE · 13 Nm · 17 rpm: Not published. Becker R12-17-C01 PLUS: Not published. Becker R12-17-C12 PLUS: Not published. Nice 230 Vac E M 1517: Not published.
Thermal protection — Gaposa XQ50 SENSE · 13 Nm · 17 rpm: Not published. Becker R12-17-C01 PLUS: Not published. Becker R12-17-C12 PLUS: Not published. Nice 230 Vac E M 1517: Not published.
IP rating — Becker R12-17-C01 PLUS: IP44 [3; 2026-10-03]; Becker R12-17-C12 PLUS: IP44 [6; 2026-10-01]; Nice 230 Vac E M 1517: IP44 [4; 2026-10-01]. Gaposa XQ50 SENSE · 13 Nm · 17 rpm: Not published.
| Property | Gaposa XQ50 SENSE · 13 Nm · 17 rpmGaposaXQ5NX1317 | Becker R12-17-C01 PLUSBecker2010 120 159 0 | Becker R12-17-C12 PLUSBecker2010 130 194 0 | Nice 230 Vac E M 1517NiceE M 1517 |
|---|---|---|---|---|
| Series & variant axes | ||||
| SeriesDiffers: XQ50 SENSE vs C01 PLUS vs C12 PLUS vs Era M | XQ50 SENSE | C01 PLUS | C12 PLUS | Era M |
| Identity & lineage | ||||
| Series / product lineDiffers: XQ50 SENSE [1; 2026-10-01] vs C01 PLUS [2; 2026-10-01] vs C12 PLUS [2; 2026-10-01] vs Not published | XQ50 SENSE [1; 2026-10-01] | C01 PLUS [2; 2026-10-01] | C12 PLUS [2; 2026-10-01] | Not published |
| GTIN / EAN | Not published | 4251852900574 [2; 2026-10-01] | 4251852916261 [2; 2026-10-01] | Not published |
| Electrical | ||||
| Rated voltage | 230 V [1; 2026-10-01] | 230 V [3; 2026-10-03] | 230 V [3; 2026-10-03] | 230 V [4; 2026-10-01] |
| Mains frequency | 50 Hz [1; 2026-10-01] | 50 Hz [3; 2026-10-03] | 50 Hz [3; 2026-10-03] | 50 Hz [4; 2026-10-01] |
| Power supply type | AC mains [1; 2026-10-01] | AC mains [3; 2026-10-03] | AC mains [3; 2026-10-03] | AC mains [4; 2026-10-01] |
| Rated power inputDiffers: Not published vs 110 W [3; 2026-10-03] vs 110 W [3; 2026-10-03] vs 170 W [4; 2026-10-01] | Not published | 110 W [3; 2026-10-03] | 110 W [3; 2026-10-03] | 170 W [4; 2026-10-01] |
| Rated currentDiffers: Not published vs 0.5 A [3; 2026-10-03] vs 0.5 A [3; 2026-10-03] vs 0.75 A [4; 2026-10-01] | Not published | 0.5 A [3; 2026-10-03] | 0.5 A [3; 2026-10-03] | 0.75 A [4; 2026-10-01] |
| Cable connection | Pluggable cable [1; 2026-10-05] | Pluggable cable [2; 2026-10-01] | Pluggable cable [2; 2026-10-01] | Not published |
| Drive performance | ||||
| Rated torqueDiffers: 13 Nm [1; 2026-10-01] vs 12 Nm [3; 2026-10-03] vs 12 Nm [3; 2026-10-03] vs 15 Nm [4; 2026-10-01] | 13 Nm [1; 2026-10-01] | 12 Nm [3; 2026-10-03] | 12 Nm [3; 2026-10-03] | 15 Nm [4; 2026-10-01] |
| Rated speed | 17 rpm [1; 2026-10-01] | 17 rpm [3; 2026-10-03] | 17 rpm [3; 2026-10-03] | 17 rpm [4; 2026-10-01] |
| Short-time duty (S2) | Not published | 4 min [3; 2026-10-03] | 4 min [3; 2026-10-03] | 4 min [4; 2026-10-01] |
| Duty type | Not published | S2 [3; 2026-10-03] | S2 [3; 2026-10-03] | Not published |
| Max load | Not published | Not published | Not published | 28 kg [4; 2026-10-01] |
| Dimensions & mounting | ||||
| Motor diameter | 45 mm [1; 2026-10-01] | 45 mm [2; 2026-10-01] | 45 mm [2; 2026-10-01] | 45 mm [5; 2026-10-07] |
| Fits tube diameter | Not published | ≥ 50 mm [2; 2026-10-01] | ≥ 50 mm [2; 2026-10-01] | Not published |
| Overall length | Not published | — | — | 451 mm [4; 2026-10-01] |
| WeightDiffers: Not published vs 1.76 kg [2; 2026-10-01] vs 1.75 kg [2; 2026-10-01] vs 2.15 kg [4; 2026-10-01] | Not published | 1.76 kg [2; 2026-10-01] | 1.75 kg [2; 2026-10-01] | 2.15 kg [4; 2026-10-01] |
| Limits & protection | ||||
| Limit setting | Not published | Not published | Not published | Mechanical [5; 2026-10-07] |
| Limit rangeDiffers: Not published vs 64 turns [3; 2026-10-03] vs 64 turns [3; 2026-10-03] vs 27 turns [4; 2026-10-01] | Not published | 64 turns [3; 2026-10-03] | 64 turns [3; 2026-10-03] | 27 turns [4; 2026-10-01] |
| Intermediate positions | Not published | 2 positions [2; 2026-10-01] | 2 positions [2; 2026-10-01] | Not published |
| Obstacle detection | Yes [1; 2026-10-01] | Yes [2; 2026-10-01] | Yes [2; 2026-10-01] | Not published |
| Soft start / soft stop | Not published | Yes [2; 2026-10-01] | Yes [2; 2026-10-01] | Not published |
| Control & communication | ||||
| Control protocol | Not published | Centronic [2; 2026-10-01] | Centronic [2; 2026-10-01] | Not published |
| Two-way feedback | Not published | Yes [2; 2026-10-01] | Yes [2; 2026-10-01] | Not published |
| Sensor inputs | Not published | Dusk [2; 2026-10-01], Frost [2; 2026-10-01], Rain [2; 2026-10-01], Sun [2; 2026-10-01], Temperature [2; 2026-10-01], Wind [2; 2026-10-01] | Dusk [2; 2026-10-01], Frost [2; 2026-10-01], Rain [2; 2026-10-01], Sun [2; 2026-10-01], Temperature [2; 2026-10-01], Wind [2; 2026-10-01] | Not published |
| Timer / astro | Not published | Yes [2; 2026-10-01] | Yes [2; 2026-10-01] | Not published |
| Environment & protection | ||||
| IP rating | Not published | IP44 [3; 2026-10-03] | IP44 [6; 2026-10-01] | IP44 [4; 2026-10-01] |
| Application | ||||
| Applications | Roller shutter [7; 2026-10-06] | Roller shutter [8; 2026-10-06] | Not published | Not published |
| Compliance & declarations | ||||
| Marks stated by vendor | Not published | CE [2; 2026-10-05] | CE [2; 2026-10-05] | Not published |
| Appearance | ||||
| Colour / finish | Not published | Weiß (RAL 9016) [2; 2026-10-01] | Weiß (RAL 9016) [2; 2026-10-01] | Not published |
| Documents | Request datasheet | Request datasheet | Request datasheet | Request datasheet |
— means no value: the manufacturer does not publish it, it does not apply to this product type, or there is none on record. Value states
Data gaps
- Becker R12-17-C01 PLUS: Overall length — Not yet collected
- Becker R12-17-C12 PLUS: Overall length — Not yet collected
Sources
- ↑Gaposa manufacturer site (product catalog)gaposa.itSeries / product line: XQ50 SENSEUsed for: 25443, 25444, 25445, 25440, 49183, 25438, 25439, 25441, 25446
- ↑Becker-Antriebe product centre (product catalog)produktcenter.becker-antriebe.comSeries / product line: Serie C01 PLUSUsed for: 12569, 17634, 12571, 17636, 12590, 17655, 12565, 17630, 12613, 17678, 12579, 17643, 12577, 17641, 12595, 17661, 12597, 17663, 12593, 17659, 12591, 17657, 12611, 12607, 12605, 12603, 12609, 12601, 17676, 17672, 17670, 17668, 17674, 17667, 12599, 17665, 48396, 48586, 12581, 17645
- ↑Becker-Antriebe GmbH PDF cataloguebecker-antriebe.comRated voltage: Nennspannung: 230 V/AC / 50Hz [2010 120 159 0] (p. 42)Used for: 47590, 47732, 47592, 47734, 47591, 47733, 47589, 47731, 47588, 47730, 47585, 47727, 47586, 47728, 47593, 47735, 47594, 47736, 47587, 47729, 47595
- ↑Nice S.p.A. PDF catalogueniceforyou.comRated voltage: Power supply (Vac/Hz): 230/50 [E M 1517] (p. 116)Used for: 38970, 38972, 38971, 38974, 38973, 38975, 38976, 38979, 38977, 38980, 38981, 38978, 38982
- ↑Nice manufacturer site (product catalog)niceforyou.comMotor diameter: Ø 45 mmUsed for: 51565, 51567
- ↑Becker-Antriebe GmbH PDF cataloguebecker-antriebe.comIP rating: Schutzart: IP44 [2010 130 194 0] (p. 24)Used for: 42130
- ↑https://www.gaposa.it/eng/prod/?residential/shutters/xq50-sense/obstacle-detection-automatic-limit-setting,-built-in-radio-and-antennagaposa.itGaposa XQ5NX1317: tubular motor listed on gaposa.it Residential > shutters (product page https://www.gaposa.it/eng/prod/?residential/shutters/xq50-sense/obstacle-detection-automatic-limit-setting,-built-in-radio-and-antenna; menus crawled 2026-10-06)Used for: 50851
- ↑https://produktcenter.becker-antriebe.com/Antriebe/Rollladenanwendungen/Antriebe-mit-integriertem-Funkempfaenger/R12-17-C01-PLUS.htmlproduktcenter.becker-antriebe.comBecker R12-17-C01 PLUS: tubular drive in produktcenter.becker-antriebe.com "Antriebe > Rollladenanwendungen" (https://produktcenter.becker-antriebe.com/Antriebe/Rollladenanwendungen/Antriebe-mit-integriertem-Funkempfaenger/R12-17-C01-PLUS.html)Used for: 50715