Compare motors
Last verified: 2026-10-05
Verifiable indicators
Short-time duty (S2) — Elero Venetian Blind drives JA / JA Soft JA 20dk: 4 min [3; 2026-10-01]; Geiger Antriebstechnik GJ56 AIR · 10 Nm · 26 rpm: 4 min [4; 2026-10-01]; Geiger Antriebstechnik GJ56 E14 Perfection · 10 Nm · 26 rpm: 4 min [5; 2026-10-01]. A-OK AM55 Silent External Venetian Blind Drive AM55-10/26-EL-HV: Not published.
Rated life — Elero Venetian Blind drives JA / JA Soft JA 20dk: Not yet collected. A-OK AM55 Silent External Venetian Blind Drive AM55-10/26-EL-HV: Not published. Geiger Antriebstechnik GJ56 AIR · 10 Nm · 26 rpm: Not published. Geiger Antriebstechnik GJ56 E14 Perfection · 10 Nm · 26 rpm: Not published.
Thermal protection — Elero Venetian Blind drives JA / JA Soft JA 20dk: Not yet collected. A-OK AM55 Silent External Venetian Blind Drive AM55-10/26-EL-HV: Not published. Geiger Antriebstechnik GJ56 AIR · 10 Nm · 26 rpm: Not published. Geiger Antriebstechnik GJ56 E14 Perfection · 10 Nm · 26 rpm: Not published.
IP rating — A-OK AM55 Silent External Venetian Blind Drive AM55-10/26-EL-HV: IP54 [1; 2026-09-30]; Geiger Antriebstechnik GJ56 AIR · 10 Nm · 26 rpm: IP54 [4; 2026-10-01]; Geiger Antriebstechnik GJ56 E14 Perfection · 10 Nm · 26 rpm: IP54 [5; 2026-10-01]. Elero Venetian Blind drives JA / JA Soft JA 20dk: Not yet collected.
| Property | Elero Venetian Blind drives JA / JA Soft JA 20dkElero350720003 | A-OK AM55 Silent External Venetian Blind Drive AM55-10/26-EL-HVA-OKAM55-10/26-EL-HV | Geiger Antriebstechnik GJ56 AIR · 10 Nm · 26 rpmGeiger AntriebstechnikGJ5610F03 | Geiger Antriebstechnik GJ56 E14 Perfection · 10 Nm · 26 rpmGeiger AntriebstechnikGJ5610 |
|---|---|---|---|---|
| Series & variant axes | ||||
| SeriesDiffers: JA / JA Soft vs AM55 vs GJ56__ AIR vs GJ56__ E14 Perfection | JA / JA Soft | AM55 | GJ56__ AIR | GJ56__ E14 Perfection |
| Identity & lineage | ||||
| Series / product lineDiffers: — vs AM55 [1; 2026-09-30] vs GJ56__ AIR [2; 2026-10-01] vs GJ56__ E14 Perfection [2; 2026-10-01] | — | AM55 [1; 2026-09-30] | GJ56__ AIR [2; 2026-10-01] | GJ56__ E14 Perfection [2; 2026-10-01] |
| Electrical | ||||
| Rated voltage | 230 V [3; 2026-10-01] | Not published | 230 V [4; 2026-10-01] | 230 V [5; 2026-10-01] |
| Supply voltage (min) | — | 110 V [1; 2026-09-30] | Not published | Not published |
| Supply voltage (max) | — | 220 V [1; 2026-09-30] | Not published | Not published |
| Mains frequency | 50 Hz [3; 2026-10-01] | 50 Hz [1; 2026-09-30], 60 Hz [1; 2026-09-30] | 50 Hz [4; 2026-10-01] | 50 Hz [5; 2026-10-01] |
| Power supply type | AC mains [3; 2026-10-01] | AC mains [1; 2026-09-30] | AC mains [4; 2026-10-01] | AC mains [5; 2026-10-01] |
| Supply rating (as stated) | — | AC110-220V / 50/60Hz [1; 2026-09-30] | 230 V~/50 Hz [2; 2026-09-23] | 230 V~/50 Hz [2; 2026-09-23] |
| Rated power inputDiffers: 230 W [3; 2026-10-01] vs 120 W [1; 2026-09-30] vs 135 W [4; 2026-10-01] vs 135 W [5; 2026-10-01] | 230 W [3; 2026-10-01] | 120 W [1; 2026-09-30] | 135 W [4; 2026-10-01] | 135 W [5; 2026-10-01] |
| Rated currentDiffers: — vs 0.55 A [1; 2026-09-30] vs 0.6 A [4; 2026-10-01] vs 0.6 A [5; 2026-10-01] | — | 0.55 A [1; 2026-09-30] | 0.6 A [4; 2026-10-01] | 0.6 A [5; 2026-10-01] |
| Power factor (cos φ) | — | Not published | > 0.95 [4; 2026-10-01] | > 0.95 [5; 2026-10-01] |
| Inrush current factor | — | Not published | 1.2 x [4; 2026-10-01] | 1.2 x [5; 2026-10-01] |
| Cable connection | — | Not published | Pluggable cable [2; 2026-10-01] | Pluggable cable [2; 2026-10-01] |
| Drive performance | ||||
| Rated torque | 10 Nm [3; 2026-10-01] | 10 Nm [1; 2026-09-30] | 10 Nm [4; 2026-10-01] | 10 Nm [5; 2026-10-01] |
| Rated speed | 26 rpm [3; 2026-10-01] | 26 rpm [1; 2026-09-30] | 26 rpm [4; 2026-10-01] | 26 rpm [5; 2026-10-01] |
| Short-time duty (S2) | 4 min [3; 2026-10-01] | Not published | 4 min [4; 2026-10-01] | 4 min [5; 2026-10-01] |
| Duty type | S2 [3; 2026-10-01] | Not published | S2 [4; 2026-10-01] | S2 [5; 2026-10-01] |
| Dimensions & mounting | ||||
| Motor diameter | — | Not published | 55 mm [4; 2026-10-01] | 55 mm [5; 2026-10-01] |
| Overall length | — | 65 mm [1; 2026-10-05] | — | — |
| WeightDifferent basis: 2.2 kg [3; 2026-10-01] vs Not published vs ≈ 1.7 kg [4; 2026-10-01] vs ≈ 1.7 kg [5; 2026-10-01] | 2.2 kg [3; 2026-10-01]Different basis | Not published | ≈ 1.7 kg [4; 2026-10-01]Different basis | ≈ 1.7 kg [5; 2026-10-01]Different basis |
| Limits & protection | ||||
| Limit setting | — | Not published | Electronic [2; 2026-10-01] | Electronic [2; 2026-10-01] |
| Limit range | — | Not published | > 200 turns [2; 2026-10-01] | > 200 turns [5; 2026-10-01] |
| Obstacle detection | — | Not published | Yes [2; 2026-10-01] | Yes [2; 2026-10-01] |
| Environment & protection | ||||
| IP rating | — | IP54 [1; 2026-09-30] | IP54 [4; 2026-10-01] | IP54 [5; 2026-10-01] |
| Operating temp. (min) | -20 °C [3; 2026-10-01] | -20 °C [1; 2026-10-01] | Not published | Not published |
| Operating temp. (max)Differs: 60 °C [3; 2026-10-01] vs 55 °C [1; 2026-10-01] vs Not published vs Not published | 60 °C [3; 2026-10-01]Highest stated | 55 °C [1; 2026-10-01] | Not published | Not published |
| Noise level | — | 48 dB(A) [1; 2026-09-30] | Not published | Not published |
| Application | ||||
| Applications | — | Not published | External venetian [2; 2026-10-01] | External venetian [2; 2026-10-01] |
| Documents | Request datasheet | Request datasheet | Request datasheet | Request datasheet |
— means no value: the manufacturer does not publish it, it does not apply to this product type, or there is none on record. Value states
Data gaps
- Elero Venetian Blind drives JA / JA Soft JA 20dk: Series / product line — Not yet collected
- Elero Venetian Blind drives JA / JA Soft JA 20dk: Rated current — Not yet collected
- Elero Venetian Blind drives JA / JA Soft JA 20dk: Overall length — Not yet collected
- Geiger Antriebstechnik GJ56 AIR · 10 Nm · 26 rpm: Overall length — Not yet collected
- Geiger Antriebstechnik GJ56 E14 Perfection · 10 Nm · 26 rpm: Overall length — Not yet collected
- Elero Venetian Blind drives JA / JA Soft JA 20dk: Limit range — Not yet collected
- Elero Venetian Blind drives JA / JA Soft JA 20dk: Control protocol — Not yet collected
- Elero Venetian Blind drives JA / JA Soft JA 20dk: IP rating — Not yet collected
Sources
- ↑A-OK Motor manufacturer site (product catalog)a-okmotor.comSeries / product line: AM55 Silent External Venetian Blind DriveUsed for: 3181, 7148, 7150, 7152, 7154, 3175, 3174, 3180, 3179, 3172, 3173, 49207, 3176, 9901, 9902, 3177
- ↑Geiger Antriebstechnik manufacturer site (product catalog)geiger.deSeries / product line: GJ56__ AIRUsed for: 5933, 8093, 779, 1411, 5937, 8097, 5936, 8096, 5929, 5935, 8095, 5934, 8094
- ↑Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title)elero.comRated voltage: Rated voltage (V): 1 ~ 230 [350720003] (p. 112)Used for: 34573, 34575, 34574, 34576, 34571, 34572, 34577, 34578, 34579, 34580, 34581
- ↑Geiger Antriebstechnik PDF cataloguegeiger.deRated voltage: Spannung: 230V~/50 Hz [GJ5610 F03] (p. 17)Used for: 32605, 32609, 32607, 32617, 32611, 32613, 32615, 32619, 32621, 32625, 32628, 32630, 32632, 32623
- ↑Geiger Antriebstechnik PDF cataloguegeiger.deRated voltage: Spannung: 230V~/50 Hz [GJ5610] (p. 21)Used for: 29935, 29937, 29936, 29941, 29938, 29939, 29940, 29942, 29943, 29946, 29947, 29948, 29949, 29945, 29944