Compare motors
Last verified: 2026-11-02
Verifiable indicators
Short-time duty (S2) — Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: 10 min [2; 2026-10-01]. Elero RolMotion M RH · 10 Nm · 14 rpm: Not published. Elero RolMotion M SH · 10 Nm · 14 rpm: Not published. Somfy 510R2 10/14 SJTW: Not published.
Rated life — Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Not yet collected. Elero RolMotion M RH · 10 Nm · 14 rpm: Not published. Elero RolMotion M SH · 10 Nm · 14 rpm: Not published. Somfy 510R2 10/14 SJTW: Not published.
Thermal protection — Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Not yet collected. Elero RolMotion M RH · 10 Nm · 14 rpm: Not published. Elero RolMotion M SH · 10 Nm · 14 rpm: Not published. Somfy 510R2 10/14 SJTW: Not published.
IP rating — Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: IP44 [2; 2026-10-01]; Somfy 510R2 10/14 SJTW: IP44 [1; 2026-09-30]. Elero RolMotion M RH · 10 Nm · 14 rpm: Not published. Elero RolMotion M SH · 10 Nm · 14 rpm: Not published.
| Property | Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SHNiceNX SOLKIT MA 1014 SH | Elero RolMotion M RH · 10 Nm · 14 rpmElero48 221.0001 | Elero RolMotion M SH · 10 Nm · 14 rpmElero49 221.0001 | Somfy 510R2 10/14 SJTWSomfy1038172 |
|---|---|---|---|---|
| Series & variant axes | ||||
| SeriesDiffers: Next Fit MA Solar Kit vs RolMotion M RH vs RolMotion M SH vs LT50 | Next Fit MA Solar Kit | RolMotion M RH | RolMotion M SH | LT50 |
| Electrical | ||||
| Rated voltage | — | Not published | Not published | 120 V [1; 2026-09-30] |
| Power supply type | — | Not published | Not published | AC mains [1; 2026-09-30] |
| Rated power input | — | Not published | Not published | 80 W [1; 2026-09-30] |
| Standby power | — | Not published | Not published | 0 W [1; 2026-10-01] |
| Drive performance | ||||
| Rated torque | 10 Nm [2; 2026-10-01] | 10 Nm [3; 2026-09-23] | 10 Nm [3; 2026-09-23] | 10 Nm [4; 2026-10-07] |
| Rated speed | 14 rpm [2; 2026-10-01] | 14 rpm [3; 2026-09-23] | 14 rpm [3; 2026-09-23] | 14 rpm [4; 2026-10-07] |
| Speed range (min) | — | 5 rpm [3; 2026-10-01] | 5 rpm [3; 2026-10-01] | Not published |
| Short-time duty (S2) | 10 min [2; 2026-10-01] | Not published | Not published | Not published |
| Dimensions & mounting | ||||
| Fits tube diameter | — | ≥ 50 mm [3; 2026-10-01] | ≥ 50 mm [3; 2026-10-01] | Not published |
| Overall length | 425 mm [2; 2026-10-01] | Not published | Not published | Not published |
| Limits & protection | ||||
| Limit setting | — | Electronic [3; 2026-10-01] | Electronic [3; 2026-10-01] | Not published |
| Control & communication | ||||
| Control interface (as stated) | — | Hardwired [3; 2026-10-01] | Hardwired [3; 2026-10-01] | Not published |
| Environment & protection | ||||
| IP rating | IP44 [2; 2026-10-01] | Not published | Not published | IP44 [1; 2026-09-30] |
| Operating temp. (min) | -20 °C [2; 2026-10-01] | Not published | Not published | Not published |
| Operating temp. (max) | 70 °C [2; 2026-10-01] | Not published | Not published | Not published |
| Noise levelDiffers: 42 dB(A) [2; 2026-11-02] vs Not published vs Not published vs 45 dB(A) [1; 2026-09-30] | 42 dB(A) [2; 2026-11-02]Lowest stated | Not published | Not published | 45 dB(A) [1; 2026-09-30] |
| Application | ||||
| Applications | — | Roller shutter [3; 2026-10-01] | Roller shutter [3; 2026-10-01] | Not published |
| Documents | Request datasheet | Request datasheet | Request datasheet | Official datasheet ↗ |
— means no value: the manufacturer does not publish it, it does not apply to this product type, or there is none on record. Value states
Data gaps
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Series / product line — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Rated voltage — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Mains frequency — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Power supply type — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Rated power input — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Standby power — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Rated current — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Cable connection — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Cable length — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Speed range (min) — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Motor diameter — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Fits tube diameter — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Weight — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Limit setting — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Limit range — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Control protocol — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Radio frequency — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Two-way feedback — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Applications — Not yet collected
- Nice Next Fit MA Solar Kit NX SOLKIT MA 1014 SH: Marks stated by vendor — Not yet collected
Sources
- ↑Somfy Systems (North America) manufacturer site (product catalog)somfysystems.comRated voltage: Power supply AC - RGE 2 - 120V/60HZUsed for: 4298, 4293, 4297, 10473, 4294, 4295
- ↑Nice S.p.A. PDF catalogueniceforyou.comRated torque: Torque (Nm): 10 [NX SOLKIT MA 1014 SH] (p. 160)Used for: 40238, 40239, 40240, 40241, 40237, 40242, 40243, 68026
- ↑Elero manufacturer site (product catalog)elero.comRated torque: 10 NmUsed for: 1679, 1669, 1680, 1670, 26207, 26182, 26206, 26181, 26205, 26180, 26203, 26178, 26204, 26179
- ↑Model-name rule somfy-explicit-torque-speed-v2: Somfy model names carrying an explicit "<Nm>/<rpm>" pair, e.g. "525A2 25/20 SJTW".somfysystems.com510R2 10/14 SJTWUsed for: 51340, 51341