Skip to main contentOpenAxia
CompareFor manufacturers

Elero Type 15/30 W vs Nice Era XL 30012

Rated power input — Elero Type 15/30 W: 1.25 W [1; 2026-10-01]; Nice Era XL 30012: 1,250 W [2; 2026-10-01].

Short-time duty (S2) — Elero Type 15/30 W: 4 min [1; 2026-10-01]; Nice Era XL 30012: 5 min [2; 2026-10-01].

Weight — Elero Type 15/30 W: 13 kg [1; 2026-10-01]; Nice Era XL 30012: 13.8 kg [2; 2026-10-01].

Last verified: 2026-10-01

When to choose Elero Type 15/30 W

When to choose Nice Era XL 30012

Verifiable indicators

Short-time duty (S2) — Elero Type 15/30 W: 4 min [1; 2026-10-01]; Nice Era XL 30012: 5 min [2; 2026-10-01].

Rated life — Elero Type 15/30 W: Not published. Nice Era XL 30012: Not yet collected.

Thermal protection — Elero Type 15/30 W: Not published. Nice Era XL 30012: Not yet collected.

IP rating — Elero Type 15/30 W: IP44 [1; 2026-10-01]; Nice Era XL 30012: IP44 [2; 2026-10-01].

Comparison table
PropertyElero Type 15/30 WElero32 381.0002Nice Era XL 30012NiceE XL 30012
Series & variant axes
SeriesDiffers: Type 15 W Typ vs Era XLType 15 W TypEra XL
Electrical
Rated voltage230 V [1; 2026-10-01]230 V [2; 2026-10-01]
Mains frequencyNot published50 Hz [2; 2026-10-01]
Power supply typeAC mains [1; 2026-10-01]AC mains [2; 2026-10-01]
Rated power inputDiffers: 1.25 W [1; 2026-10-01] vs 1,250 W [2; 2026-10-01]1.25 W [1; 2026-10-01]1,250 W [2; 2026-10-01]
Rated current5.5 A [1; 2026-10-01]5.4 A [2; 2026-10-01]
Drive performance
Rated torque300 Nm [1; 2026-10-01]300 Nm [2; 2026-10-01]
Rated speed12 rpm [1; 2026-10-01]12 rpm [2; 2026-10-01]
Short-time duty (S2)Differs: 4 min [1; 2026-10-01] vs 5 min [2; 2026-10-01]4 min [1; 2026-10-01]5 min [2; 2026-10-01]Highest stated
Duty typeS2 [1; 2026-10-01]—
Max loadNot published405 kg [2; 2026-10-01]
Dimensions & mounting
Fits tube diameter≥ 98 mm [3; 2026-10-01]—
WeightDiffers: 13 kg [1; 2026-10-01] vs 13.8 kg [2; 2026-10-01]13 kg [1; 2026-10-01]13.8 kg [2; 2026-10-01]
Limits & protection
Limit range36 turns [1; 2026-10-01]36 turns [2; 2026-10-01]
Control & communication
Control interface (as stated)Hardwired [3; 2026-10-01]—
Environment & protection
IP ratingIP44 [1; 2026-10-01]IP44 [2; 2026-10-01]
Operating temp. (min)-20 °C [1; 2026-10-01]—
Operating temp. (max)60 °C [1; 2026-10-01]—
DocumentsRequest datasheetRequest datasheet

— means no value: the manufacturer does not publish it, it does not apply to this product type, or there is none on record. Value states

Series

Data gaps

  • Nice Era XL 30012: Series / product line — Not yet collected
  • Nice Era XL 30012: Standby power — Not yet collected
  • Nice Era XL 30012: Cable connection — Not yet collected
  • Nice Era XL 30012: Cable length — Not yet collected
  • Nice Era XL 30012: Speed range (min) — Not yet collected
  • Nice Era XL 30012: Motor diameter — Not yet collected
  • Nice Era XL 30012: Fits tube diameter — Not yet collected
  • Nice Era XL 30012: Overall length — Not yet collected
  • Nice Era XL 30012: Limit setting — Not yet collected
  • Nice Era XL 30012: Control protocol — Not yet collected
  • Nice Era XL 30012: Radio frequency — Not yet collected
  • Nice Era XL 30012: Two-way feedback — Not yet collected
  • Nice Era XL 30012: Operating temp. (min) — Not yet collected
  • Nice Era XL 30012: Operating temp. (max) — Not yet collected
  • Nice Era XL 30012: Noise level — Not yet collected
  • Elero Type 15/30 W: Applications — Not yet collected
  • Nice Era XL 30012: Applications — Not yet collected
  • Nice Era XL 30012: Marks stated by vendor — Not yet collected

Questions and answers

What supply voltage and frequency does each use?
Rated voltage — Elero Type 15/30 W: 230 V; Nice Era XL 30012: 230 V. Mains frequency — Nice Era XL 30012: 50 Hz. Power supply type — Elero Type 15/30 W: AC mains; Nice Era XL 30012: AC mains.
What torque and speed is each rated for?
Rated torque — Elero Type 15/30 W: 300 Nm; Nice Era XL 30012: 300 Nm. Rated speed — Elero Type 15/30 W: 12 rpm; Nice Era XL 30012: 12 rpm. Max load — Nice Era XL 30012: 405 kg.
Which durability indicators does each publish?
OpenAxia does not rate reliability; the published indicators are: Short-time duty (S2) — Elero Type 15/30 W: 4 min; Nice Era XL 30012: 5 min. IP rating — Elero Type 15/30 W: IP44; Nice Era XL 30012: IP44.

Sources

  1. ↑Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title)elero.comRated voltage: Rated voltage (V): 1 ~ 230 [323810002] (p. 246)Manufacturer-stated · Observed 2026-10-01 · Retrieved 2026-10-01 · Public web pageUsed for: 35312, 35313, 35315, 35314, 35310, 35311, 35316, 35317, 35320, 35319, 35318, 35321, 35322
  2. ↑Nice S.p.A. PDF catalogueniceforyou.comRated voltage: Power supply (Vac/Hz): 230/50 [E XL 30012] (p. 188)Manufacturer-stated · Observed 2026-10-01 · Retrieved 2026-10-01 · Public web pageUsed for: 40703, 40705, 40704, 40707, 40706, 40708, 40709, 40712, 40710, 40713, 40711, 40714
  3. ↑Elero manufacturer site (product catalog)elero.comFits tube (min.): Shaft size (mm) from 98Manufacturer-stated · Observed 2026-10-01 · Retrieved 2026-09-23 · Public web pageUsed for: 27842, 27841
See something wrong? Report an error