Skip to main contentOpenAxia
CompareFor manufacturers

Elero Type 15/12 W vs Becker L120-11-E25

Rated power input — Elero Type 15/12 W: 700 W [2; 2026-10-01]; Becker L120-11-E25: 435 W [3; 2026-10-03].

Rated current — Elero Type 15/12 W: 3.4 A [2; 2026-10-01]; Becker L120-11-E25: 1.9 A [3; 2026-10-03].

Rated speed — Elero Type 15/12 W: 12 rpm [2; 2026-10-01]; Becker L120-11-E25: 11 rpm [3; 2026-10-03].

Last verified: 2026-10-06

When to choose Elero Type 15/12 W

When to choose Becker L120-11-E25

Verifiable indicators

Short-time duty (S2) — Elero Type 15/12 W: 6 min [2; 2026-10-01]; Becker L120-11-E25: 4 min [3; 2026-10-03].

Rated life — Elero Type 15/12 W: Not published. Becker L120-11-E25: Not published.

Thermal protection — Elero Type 15/12 W: Not published. Becker L120-11-E25: Not published.

IP rating — Elero Type 15/12 W: IP44 [2; 2026-10-01]; Becker L120-11-E25: IP44 [3; 2026-10-03].

Comparison table
PropertyElero Type 15/12 WElero32 301.0002Becker L120-11-E25Becker2120 140 006 0
Series & variant axes
SeriesDiffers: Type 15 W Typ vs E25Type 15 W TypE25
Identity & lineage
Series / product lineNot publishedE25 [1; 2026-10-01]
GTIN / EANNot published4251852902752 [1; 2026-10-01]
Electrical
Rated voltage230 V [2; 2026-10-01]230 V [3; 2026-10-03]
Mains frequencyNot published50 Hz [3; 2026-10-03]
Power supply typeAC mains [2; 2026-10-01]AC mains [3; 2026-10-03]
Rated power inputDiffers: 700 W [2; 2026-10-01] vs 435 W [3; 2026-10-03]700 W [2; 2026-10-01]435 W [3; 2026-10-03]
Rated currentDiffers: 3.4 A [2; 2026-10-01] vs 1.9 A [3; 2026-10-03]3.4 A [2; 2026-10-01]1.9 A [3; 2026-10-03]
Cable typeNot publishedGummileitung H05RR-F 4G0,75 sw [1; 2026-10-05]
Cable lengthNot published0.09 m [1; 2026-10-05]
Drive performance
Rated torque120 Nm [2; 2026-10-01]120 Nm [3; 2026-10-03]
Rated speedDiffers: 12 rpm [2; 2026-10-01] vs 11 rpm [3; 2026-10-03]12 rpm [2; 2026-10-01]11 rpm [3; 2026-10-03]
Short-time duty (S2)Differs: 6 min [2; 2026-10-01] vs 4 min [3; 2026-10-03]6 min [2; 2026-10-01]Highest stated4 min [3; 2026-10-03]
Duty typeS2 [2; 2026-10-01]S2 [3; 2026-10-03]
Dimensions & mounting
Motor diameterNot published58 mm [1; 2026-10-01]
Fits tube diameterDiffers: ≥ 98 mm [4; 2026-10-01] vs ≥ 63 mm [1; 2026-10-01]≥ 98 mm [4; 2026-10-01]≥ 63 mm [1; 2026-10-01]
WeightDiffers: 11.4 kg [2; 2026-10-01] vs 5.1 kg [1; 2026-10-01]11.4 kg [2; 2026-10-01]5.1 kg [1; 2026-10-01]
Limits & protection
Limit settingNot publishedElectronic [1; 2026-10-01]
Limit rangeDiffers: 36 turns [2; 2026-10-01] vs 64 turns [3; 2026-10-03]36 turns [2; 2026-10-01]64 turns [3; 2026-10-03]
Obstacle detectionNot publishedYes [1; 2026-10-01]
Soft start / soft stopNot publishedYes [1; 2026-10-01]
Control & communication
Control interface (as stated)Hardwired [4; 2026-10-01]Not published
Environment & protection
IP ratingIP44 [2; 2026-10-01]IP44 [3; 2026-10-03]
Operating temp. (min)-20 °C [2; 2026-10-01]Not published
Operating temp. (max)60 °C [2; 2026-10-01]Not published
Application
Applications—Roller shutter [5; 2026-10-06]
Compliance & declarations
Marks stated by vendorNot publishedCE [1; 2026-10-05]
Appearance
Colour / finishNot publishedWeiß (RAL 9016) [1; 2026-10-01]
DocumentsRequest datasheetRequest datasheet

— means no value: the manufacturer does not publish it, it does not apply to this product type, or there is none on record. Value states

Series

Cross-brand alternatives

Data gaps

  • Becker L120-11-E25: Overall length — Not yet collected
  • Elero Type 15/12 W: Applications — Not yet collected

Questions and answers

What supply voltage and frequency does each use?
Rated voltage — Elero Type 15/12 W: 230 V; Becker L120-11-E25: 230 V. Mains frequency — Becker L120-11-E25: 50 Hz. Power supply type — Elero Type 15/12 W: AC mains; Becker L120-11-E25: AC mains.
What torque and speed is each rated for?
Rated torque — Elero Type 15/12 W: 120 Nm; Becker L120-11-E25: 120 Nm. Rated speed — Elero Type 15/12 W: 12 rpm; Becker L120-11-E25: 11 rpm.
What certifications are on record for each?
Marks stated by vendor — Becker L120-11-E25: CE.
Which durability indicators does each publish?
OpenAxia does not rate reliability; the published indicators are: Short-time duty (S2) — Elero Type 15/12 W: 6 min; Becker L120-11-E25: 4 min. IP rating — Elero Type 15/12 W: IP44; Becker L120-11-E25: IP44.

Sources

  1. ↑Becker-Antriebe product centre (product catalog)produktcenter.becker-antriebe.comSeries / product line: Serie E25Manufacturer-stated · Observed 2026-10-01 · Retrieved 2026-10-01 · Public web pageUsed for: 15204, 15206, 48494, 48496, 15200, 15226, 15211, 15228, 15222, 15224, 48495, 15212
  2. ↑Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title)elero.comRated voltage: Rated voltage (V): 1 ~ 230 [323010002] (p. 246)Manufacturer-stated · Observed 2026-10-01 · Retrieved 2026-10-01 · Public web pageUsed for: 35260, 35261, 35263, 35262, 35258, 35259, 35264, 35265, 35268, 35267, 35266, 35269, 35270
  3. ↑Becker-Antriebe GmbH PDF cataloguebecker-antriebe.comRated voltage: Nennspannung: 230 V/AC / 50Hz [2120 140 006 0] (p. 23)Manufacturer-stated · Observed 2026-10-03 · Retrieved 2026-10-03 · Public web pageUsed for: 46699, 46701, 46700, 46698, 46697, 46694, 46695, 46702, 46703, 46696, 46704
  4. ↑Elero manufacturer site (product catalog)elero.comFits tube (min.): Shaft size (mm) from 98Manufacturer-stated · Observed 2026-10-01 · Retrieved 2026-09-23 · Public web pageUsed for: 27834, 27833
  5. ↑https://produktcenter.becker-antriebe.com/Antriebe/Rollladenanwendungen/Antriebe-mit-elektronischer-Endabschaltung/L120-11-E25.htmlproduktcenter.becker-antriebe.comBecker L120-11-E25: tubular drive in produktcenter.becker-antriebe.com "Antriebe > Rollladenanwendungen" (https://produktcenter.becker-antriebe.com/Antriebe/Rollladenanwendungen/Antriebe-mit-elektronischer-Endabschaltung/L120-11-E25.html)Manufacturer-stated · Observed 2026-10-06 · Retrieved 2026-10-06 · Public web pageUsed for: 50670
See something wrong? Report an error