Elero RolTop M RH · 12 Nm · 23 rpm vs Elero RolTop M RH · 20 Nm · 14 rpm

Rated torque — Elero RolTop M RH · 12 Nm [1; 2026-11-02] · 23 rpm: 12 Nm; Elero RolTop M RH · 20 Nm [1; 2026-10-01] · 14 rpm: 20 Nm.

Rated speed — Elero RolTop M RH · 12 Nm · 23 rpm [1; 2026-11-02]: 23 rpm; Elero RolTop M RH · 20 Nm · 14 rpm [1; 2026-10-01]: 14 rpm.

Short-time duty (S2) — Elero RolTop M RH · 12 Nm · 23 rpm: 5 min [1; 2026-11-02]; Elero RolTop M RH · 20 Nm · 14 rpm: 4 min [1; 2026-10-01].

Last verified: 2026-11-02

When to choose Elero RolTop M RH · 12 Nm · 23 rpm

When to choose Elero RolTop M RH · 20 Nm · 14 rpm

Verifiable indicators

Short-time duty (S2) — Elero RolTop M RH · 12 Nm · 23 rpm: 5 min [1; 2026-11-02]; Elero RolTop M RH · 20 Nm · 14 rpm: 4 min [1; 2026-10-01].

Rated life — Elero RolTop M RH · 12 Nm · 23 rpm: Not published. Elero RolTop M RH · 20 Nm · 14 rpm: Not published.

Thermal protection — Elero RolTop M RH · 12 Nm · 23 rpm: Not published. Elero RolTop M RH · 20 Nm · 14 rpm: Not published.

IP rating — Elero RolTop M RH · 12 Nm · 23 rpm: Not published. Elero RolTop M RH · 20 Nm · 14 rpm: Not published.

Comparison table
PropertyElero RolTop M RH · 12 Nm · 23 rpmElero38 235.0001Elero RolTop M RH · 20 Nm · 14 rpmElero38 231.0001
Series & variant axes
SeriesRolTop M RHRolTop M RH
TorqueDiffers: 12 Nm vs 20 Nm12 Nm20 Nm
Rated speedDiffers: 23 rpm vs 14 rpm23 rpm14 rpm
Electrical
Rated voltage230 V [1; 2026-11-02]230 V [1; 2026-10-01]
Mains frequency50 Hz [1; 2026-11-02]50 Hz [1; 2026-10-01]
Power supply typeAC mains [1; 2026-11-02]AC mains [1; 2026-10-01]
Rated power input200 W [1; 2026-11-02]200 W [1; 2026-10-01]
Rated current0.9 A [1; 2026-11-02]0.9 A [1; 2026-10-01]
Drive performance
Rated torqueDiffers: 12 Nm [1; 2026-11-02] vs 20 Nm [1; 2026-10-01]12 Nm [1; 2026-11-02]20 Nm [1; 2026-10-01]
Rated speedDiffers: 23 rpm [1; 2026-11-02] vs 14 rpm [1; 2026-10-01]23 rpm [1; 2026-11-02]14 rpm [1; 2026-10-01]
Short-time duty (S2)Differs: 5 min [1; 2026-11-02] vs 4 min [1; 2026-10-01]5 min [1; 2026-11-02]Highest stated4 min [1; 2026-10-01]
Duty typeS2 [1; 2026-11-02]S2 [1; 2026-10-01]
Dimensions & mounting
Fits tube diameter≥ 50 mm [2; 2026-10-02]≥ 50 mm [2; 2026-10-01]
WeightDiffers: 1.9 kg [1; 2026-11-02] vs 2.1 kg [1; 2026-10-01]1.9 kg [1; 2026-11-02]2.1 kg [1; 2026-10-01]
Limits & protection
Limit settingElectronic [2; 2026-10-02]Electronic [2; 2026-10-01]
Control & communication
Control interface (as stated)Hardwired [2; 2026-10-02]Hardwired [2; 2026-10-01]
Application
ApplicationsRoller blind [2; 2026-10-05], Roller shutter [2; 2026-10-02], Screen [2; 2026-10-02]Roller blind [2; 2026-10-05], Roller shutter [2; 2026-10-01], Screen [2; 2026-10-01]
View all 5 variants
DocumentsRequest datasheetRequest datasheet

Same-series variants

Variant axisElero RolTop M RH · 12 Nm · 23 rpmElero RolTop M RH · 20 Nm · 14 rpm
Torque12 Nm [Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title); 2026-11-02]20 Nm [Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title); 2026-10-01]
Rated speed23 rpm [Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title); 2026-11-02]14 rpm [Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title); 2026-10-01]

Questions and answers

What supply voltage and frequency does each use?
Rated voltage — Elero RolTop M RH · 12 Nm · 23 rpm: 230 V; Elero RolTop M RH · 20 Nm · 14 rpm: 230 V. Mains frequency — Elero RolTop M RH · 12 Nm · 23 rpm: 50 Hz; Elero RolTop M RH · 20 Nm · 14 rpm: 50 Hz. Power supply type — Elero RolTop M RH · 12 Nm · 23 rpm: AC mains; Elero RolTop M RH · 20 Nm · 14 rpm: AC mains.
What torque and speed is each rated for?
Rated torque — Elero RolTop M RH · 12 Nm · 23 rpm: 12 Nm; Elero RolTop M RH · 20 Nm · 14 rpm: 20 Nm. Rated speed — Elero RolTop M RH · 12 Nm · 23 rpm: 23 rpm; Elero RolTop M RH · 20 Nm · 14 rpm: 14 rpm.
What protocols and control options does each support?
Limit setting — Elero RolTop M RH · 12 Nm · 23 rpm: Electronic; Elero RolTop M RH · 20 Nm · 14 rpm: Electronic.
Which durability indicators does each publish?
OpenAxia does not rate reliability; the published indicators are: Short-time duty (S2) — Elero RolTop M RH · 12 Nm · 23 rpm: 5 min; Elero RolTop M RH · 20 Nm · 14 rpm: 4 min.

Sources

  1. ↑Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title)elero.comRated voltage: Rated voltage (V): 1 ~ 230 [382350001] (p. 55)Manufacturer-stated · Observed 2026-11-02 · Retrieved 2026-11-02 · Public web pageUsed for: 67801, 33257, 67803, 33259, 67802, 33258, 67805, 33261, 67804, 33260, 67799, 33255, 67800, 33256, 67806, 33262, 67807, 33263, 67808, 33264
  2. ↑Elero manufacturer site (product catalog)elero.comFits tube (min.): Shaft size (mm) from 50Manufacturer-stated · Observed 2026-10-02 · Retrieved 2026-09-23 · Public web pageUsed for: 45879, 27717, 45880, 27716, 45881, 27713, 49090, 45882, 45883, 49086, 27714, 27715
See something wrong? Report an error