Skip to main contentOpenAxia
CompareFor manufacturers

Elero RolTop M RH · 10 Nm · 14 rpm vs Elero RolTop M RH · 7 Nm · 23 rpm

Rated torque — Elero RolTop M RH · 10 Nm [1; 2026-10-01] · 14 rpm: 10 Nm; Elero RolTop M RH · 7 Nm [2; 2026-10-02] · 23 rpm: 7 Nm.

Rated speed — Elero RolTop M RH · 10 Nm · 14 rpm [1; 2026-10-01]: 14 rpm; Elero RolTop M RH · 7 Nm · 23 rpm [2; 2026-10-02]: 23 rpm.

Last verified: 2026-10-05

When to choose Elero RolTop M RH · 10 Nm · 14 rpm

When to choose Elero RolTop M RH · 7 Nm · 23 rpm

Verifiable indicators

Short-time duty (S2) — Elero RolTop M RH · 10 Nm · 14 rpm: 5 min [1; 2026-10-01]. Elero RolTop M RH · 7 Nm · 23 rpm: Not published.

Rated life — Elero RolTop M RH · 10 Nm · 14 rpm: Not published. Elero RolTop M RH · 7 Nm · 23 rpm: Not published.

Thermal protection — Elero RolTop M RH · 10 Nm · 14 rpm: Not published. Elero RolTop M RH · 7 Nm · 23 rpm: Not published.

IP rating — Elero RolTop M RH · 10 Nm · 14 rpm: Not published. Elero RolTop M RH · 7 Nm · 23 rpm: Not published.

Comparison table
PropertyElero RolTop M RH · 10 Nm · 14 rpmElero38 221.0001Elero RolTop M RH · 7 Nm · 23 rpmElero38 225.0001
Series & variant axes
SeriesRolTop M RHRolTop M RH
TorqueDiffers: 10 Nm vs 7 Nm10 Nm7 Nm
Rated speedDiffers: 14 rpm vs 23 rpm14 rpm23 rpm
Electrical
Rated voltage230 V [1; 2026-10-01]Not published
Mains frequency50 Hz [1; 2026-10-01]Not published
Power supply typeAC mains [1; 2026-10-01]Not published
Rated power input140 W [1; 2026-10-01]Not published
Rated current0.6 A [1; 2026-10-01]Not published
Drive performance
Rated torqueDiffers: 10 Nm [1; 2026-10-01] vs 7 Nm [2; 2026-10-02]10 Nm [1; 2026-10-01]7 Nm [2; 2026-10-02]
Rated speedDiffers: 14 rpm [1; 2026-10-01] vs 23 rpm [2; 2026-10-02]14 rpm [1; 2026-10-01]23 rpm [2; 2026-10-02]
Short-time duty (S2)5 min [1; 2026-10-01]Not published
Duty typeS2 [1; 2026-10-01]Not published
Dimensions & mounting
Fits tube diameter≥ 50 mm [2; 2026-10-01]≥ 50 mm [2; 2026-10-02]
Weight1.7 kg [1; 2026-10-01]Not published
Limits & protection
Limit settingElectronic [2; 2026-10-01]Electronic [2; 2026-10-02]
Control & communication
Control interface (as stated)Hardwired [2; 2026-10-01]Hardwired [2; 2026-10-02]
Application
ApplicationsRoller blind [2; 2026-10-05], Roller shutter [2; 2026-10-01], Screen [2; 2026-10-01]Roller blind [2; 2026-10-05], Roller shutter [2; 2026-10-02], Screen [2; 2026-10-02]
View all 5 variants
DocumentsRequest datasheetRequest datasheet

Same-series variants

Variant axisElero RolTop M RH · 10 Nm · 14 rpmElero RolTop M RH · 7 Nm · 23 rpm
Torque10 Nm [Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title); 2026-10-01]7 Nm [Elero manufacturer site (product catalog); 2026-10-02]
Rated speed14 rpm [Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title); 2026-10-01]23 rpm [Elero manufacturer site (product catalog); 2026-10-02]

Questions and answers

What torque and speed is each rated for?
Rated torque — Elero RolTop M RH · 10 Nm · 14 rpm: 10 Nm; Elero RolTop M RH · 7 Nm · 23 rpm: 7 Nm. Rated speed — Elero RolTop M RH · 10 Nm · 14 rpm: 14 rpm; Elero RolTop M RH · 7 Nm · 23 rpm: 23 rpm.
What protocols and control options does each support?
Limit setting — Elero RolTop M RH · 10 Nm · 14 rpm: Electronic; Elero RolTop M RH · 7 Nm · 23 rpm: Electronic.
Which durability indicators does each publish?
OpenAxia does not rate reliability; the published indicators are: Short-time duty (S2) — Elero RolTop M RH · 10 Nm · 14 rpm: 5 min.

Sources

  1. ↑Elero GmbH PDF catalogue elero_Catalog_2026_oP_08-26_EN.pdf (Title)elero.comRated voltage: Rated voltage (V): 1 ~ 230 [382210001] (p. 55)Manufacturer-stated · Observed 2026-10-01 · Retrieved 2026-10-01 · Public web pageUsed for: 33207, 33209, 33208, 33211, 33210, 33205, 33206, 33212, 33213, 33214
  2. ↑Elero manufacturer site (product catalog)elero.comRated torque: 7 NmManufacturer-stated · Observed 2026-10-02 · Retrieved 2026-09-23 · Public web pageUsed for: 45870, 45871, 27707, 45872, 27706, 45873, 27703, 45874, 49084, 27704, 27705, 49089, 45875, 45876
See something wrong? Report an error