Skip to main contentOpenAxia
CompareFor manufacturers

Becker L70-17-C12 PLUS vs Becker L60-11-C12 PLUS

Rated power input — Becker L70-17-C12 PLUS: 430 W [2; 2026-10-03]; Becker L60-11-C12 PLUS: 265 W [2; 2026-10-03].

Rated current — Becker L70-17-C12 PLUS: 1.9 A [2; 2026-10-03]; Becker L60-11-C12 PLUS: 1.2 A [2; 2026-10-03].

Rated torque — Becker L70-17-C12 PLUS: 70 Nm [2; 2026-10-03]; Becker L60-11-C12 PLUS: 60 Nm [2; 2026-10-03].

Last verified: 2026-10-05

When to choose Becker L70-17-C12 PLUS

When to choose Becker L60-11-C12 PLUS

Verifiable indicators

Short-time duty (S2) — Becker L70-17-C12 PLUS: 4 min [2; 2026-10-03]; Becker L60-11-C12 PLUS: 4 min [2; 2026-10-03].

Rated life — Becker L70-17-C12 PLUS: Not published. Becker L60-11-C12 PLUS: Not published.

Thermal protection — Becker L70-17-C12 PLUS: Not published. Becker L60-11-C12 PLUS: Not published.

IP rating — Becker L70-17-C12 PLUS: IP44 [2; 2026-10-03]; Becker L60-11-C12 PLUS: IP44 [2; 2026-10-03].

Comparison table
PropertyBecker L70-17-C12 PLUSBecker2070 130 139 0Becker L60-11-C12 PLUSBecker2060 130 161 0
Series & variant axes
SeriesC12 PLUSC12 PLUS
Identity & lineage
GTIN / EAN4251852916605 [1; 2026-10-01]4251852916612 [1; 2026-10-01]
Electrical
Rated voltage230 V [2; 2026-10-03]230 V [2; 2026-10-03]
Mains frequency50 Hz [2; 2026-10-03]50 Hz [2; 2026-10-03]
Power supply typeAC mains [2; 2026-10-03]AC mains [2; 2026-10-03]
Rated power inputDiffers: 430 W [2; 2026-10-03] vs 265 W [2; 2026-10-03]430 W [2; 2026-10-03]265 W [2; 2026-10-03]
Rated currentDiffers: 1.9 A [2; 2026-10-03] vs 1.2 A [2; 2026-10-03]1.9 A [2; 2026-10-03]1.2 A [2; 2026-10-03]
Cable connectionPluggable cable [1; 2026-10-01]Pluggable cable [1; 2026-10-01]
Drive performance
Rated torqueDiffers: 70 Nm [2; 2026-10-03] vs 60 Nm [2; 2026-10-03]70 Nm [2; 2026-10-03]60 Nm [2; 2026-10-03]
Rated speedDiffers: 17 rpm [2; 2026-10-03] vs 11 rpm [2; 2026-10-03]17 rpm [2; 2026-10-03]11 rpm [2; 2026-10-03]
Short-time duty (S2)4 min [2; 2026-10-03]4 min [2; 2026-10-03]
Duty typeS2 [2; 2026-10-03]S2 [2; 2026-10-03]
Dimensions & mounting
Motor diameter58 mm [1; 2026-10-01]58 mm [1; 2026-10-01]
Fits tube diameter≥ 63 mm [1; 2026-10-01]≥ 63 mm [1; 2026-10-01]
WeightDiffers: 4.391 kg [1; 2026-10-01] vs 4.057 kg [1; 2026-10-01]4.391 kg [1; 2026-10-01]4.057 kg [1; 2026-10-01]
Limits & protection
Limit range64 turns [2; 2026-10-03]64 turns [2; 2026-10-03]
Intermediate positions2 positions [1; 2026-10-01]2 positions [1; 2026-10-01]
Obstacle detectionYes [1; 2026-10-01]Yes [1; 2026-10-01]
Soft start / soft stopYes [1; 2026-10-01]Yes [1; 2026-10-01]
Control & communication
Control protocolCentronic [1; 2026-10-01]Centronic [1; 2026-10-01]
Two-way feedbackYes [1; 2026-10-01]Yes [1; 2026-10-01]
Sensor inputsDusk [1; 2026-10-01], Frost [1; 2026-10-01], Rain [1; 2026-10-01], Sun [1; 2026-10-01], Temperature [1; 2026-10-01], Wind [1; 2026-10-01]Dusk [1; 2026-10-01], Frost [1; 2026-10-01], Rain [1; 2026-10-01], Sun [1; 2026-10-01], Temperature [1; 2026-10-01], Wind [1; 2026-10-01]
Timer / astroYes [1; 2026-10-01]Yes [1; 2026-10-01]
Environment & protection
IP ratingIP44 [2; 2026-10-03]IP44 [2; 2026-10-03]
Compliance & declarations
Marks stated by vendorCE [1; 2026-10-05]CE [1; 2026-10-05]
Appearance
Colour / finishWeiß (RAL 9016) [1; 2026-10-01]Weiß (RAL 9016) [1; 2026-10-01]
View all 14 variants
DocumentsRequest datasheetRequest datasheet

Cross-brand alternatives

Data gaps

  • Becker L70-17-C12 PLUS: Overall length — Not yet collected
  • Becker L60-11-C12 PLUS: Overall length — Not yet collected

Questions and answers

What supply voltage and frequency does each use?
Rated voltage — Becker L70-17-C12 PLUS: 230 V; Becker L60-11-C12 PLUS: 230 V. Mains frequency — Becker L70-17-C12 PLUS: 50 Hz; Becker L60-11-C12 PLUS: 50 Hz. Power supply type — Becker L70-17-C12 PLUS: AC mains; Becker L60-11-C12 PLUS: AC mains.
Which tube diameters do they fit?
Motor diameter — Becker L70-17-C12 PLUS: 58 mm; Becker L60-11-C12 PLUS: 58 mm.
What torque and speed is each rated for?
Rated torque — Becker L70-17-C12 PLUS: 70 Nm; Becker L60-11-C12 PLUS: 60 Nm. Rated speed — Becker L70-17-C12 PLUS: 17 rpm; Becker L60-11-C12 PLUS: 11 rpm.
What protocols and control options does each support?
Control protocol — Becker L70-17-C12 PLUS: Centronic; Becker L60-11-C12 PLUS: Centronic.

Sources

  1. ↑Becker-Antriebe product centre (product catalog)produktcenter.becker-antriebe.comSeries / product line: Serie C12 PLUSManufacturer-stated · Observed 2026-10-01 · Retrieved 2026-10-01 · Public web pageUsed for: 18164, 18090, 18165, 18091, 18175, 18110, 18161, 18086, 18187, 18133, 18169, 18098, 18168, 18097, 18178, 18116, 18179, 18118, 18177, 18114, 18176, 18112, 18186, 18184, 18183, 18182, 18185, 18181, 18131, 18127, 18126, 18124, 18129, 18122, 18180, 18120, 48593, 48592, 18170, 18100
  2. ↑Becker-Antriebe GmbH PDF cataloguebecker-antriebe.comRated voltage: Nennspannung: 230 V/AC / 50Hz [2070 130 139 0] (p. 46)Manufacturer-stated · Observed 2026-10-03 · Retrieved 2026-10-03 · Public web pageUsed for: 47804, 47793, 47806, 47795, 47805, 47794, 47803, 47792, 47802, 47791, 47799, 47788, 47800, 47789, 47807, 47796, 47808, 47797, 47801, 47790, 47809, 47798
See something wrong? Report an error