Rated voltage — Becker L50-17-M04: 230 V [3; 2026-10-03]; A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: 18 V [2; 2026-09-30].

Rated power input — Becker L50-17-M04: 315 W [3; 2026-10-03]; A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: 130 W [2; 2026-09-30].

Rated current — Becker L50-17-M04: 1.4 A [3; 2026-10-03]; A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: 7 A [2; 2026-09-30].

Last verified: 2026-10-06

When to choose Becker L50-17-M04

When to choose A-OK AM45 Ultra-Quiet Battery Powered Awning Motor

Verifiable indicators

Short-time duty (S2) — Becker L50-17-M04: 4 min [3; 2026-10-03]. A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: Not published.

Rated life — Becker L50-17-M04: Not published. A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: Not published.

Thermal protection — Becker L50-17-M04: Not published. A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: Not published.

IP rating — Becker L50-17-M04: IP44 [3; 2026-10-03]; A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: IP44 [2; 2026-09-30].

Comparison table
PropertyBecker L50-17-M04Becker2050 110 106 0A-OK AM45 Ultra-Quiet Battery Powered Awning MotorA-OKAM45C-50/6-ES-E
Series & variant axes
SeriesDiffers: M04 vs AM45M04AM45
Identity & lineage
GTIN / EAN4251852900987 [1; 2026-10-01]Not published
Electrical
Rated voltageDiffers: 230 V [3; 2026-10-03] vs 18 V [2; 2026-09-30]230 V [3; 2026-10-03]18 V [2; 2026-09-30]
Mains frequency50 Hz [3; 2026-10-03]Not published
Power supply typeDiffers: AC mains [3; 2026-10-03] vs Battery, DC [2; 2026-09-30] [2; 2026-10-01]AC mains [3; 2026-10-03]Battery [2; 2026-09-30], DC [2; 2026-10-01]
Rated power inputDiffers: 315 W [3; 2026-10-03] vs 130 W [2; 2026-09-30]315 W [3; 2026-10-03]130 W [2; 2026-09-30]
Rated currentDiffers: 1.4 A [3; 2026-10-03] vs 7 A [2; 2026-09-30]1.4 A [3; 2026-10-03]7 A [2; 2026-09-30]
Cable connectionPluggable cable [1; 2026-10-01]Not published
Drive performance
Rated torque50 Nm [3; 2026-10-03]50 Nm [2; 2026-09-30]
Rated speedDiffers: 17 rpm [3; 2026-10-03] vs 6 rpm [2; 2026-09-30]17 rpm [3; 2026-10-03]6 rpm [2; 2026-09-30]
Short-time duty (S2)4 min [3; 2026-10-03]Not published
Duty typeS2 [3; 2026-10-03]Not published
Dimensions & mounting
Motor diameter58 mm [1; 2026-10-01]Not published
Fits tube diameter≥ 63 mm [1; 2026-10-01]Not published
Weight4.739 kg [1; 2026-10-01]Not published
Limits & protection
Limit settingMechanical [1; 2026-10-01]Not published
Limit range36 turns [3; 2026-10-03]Not published
Control & communication
Radio frequencyNot published868 MHz [2; 2026-10-01]
Environment & protection
IP ratingIP44 [3; 2026-10-03]IP44 [2; 2026-09-30]
Operating temp. (min)Not published-20 °C [2; 2026-09-30]
Operating temp. (max)Not published65 °C [2; 2026-09-30]
Application
ApplicationsDiffers: Roller shutter [4; 2026-10-06] vs Awning, Screen [5; 2026-10-06] [5; 2026-10-06]Roller shutter [4; 2026-10-06]Awning [5; 2026-10-06], Screen [5; 2026-10-06]
Compliance & declarations
Marks stated by vendorCE [1; 2026-10-05]Not published
Appearance
Colour / finishWeiß (RAL 9016) [1; 2026-10-01]Not published
DocumentsRequest datasheetRequest datasheet

Series

Cross-brand alternatives

Data gaps

  • Becker L50-17-M04: Overall length — Not yet collected

Questions and answers

What supply voltage and frequency does each use?
Rated voltage — Becker L50-17-M04: 230 V; A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: 18 V. Mains frequency — Becker L50-17-M04: 50 Hz. Power supply type — Becker L50-17-M04: AC mains; A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: Battery, DC.
What torque and speed is each rated for?
Rated torque — Becker L50-17-M04: 50 Nm; A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: 50 Nm. Rated speed — Becker L50-17-M04: 17 rpm; A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: 6 rpm.
What certifications are on record for each?
Marks stated by vendor — Becker L50-17-M04: CE.
Which durability indicators does each publish?
OpenAxia does not rate reliability; the published indicators are: Short-time duty (S2) — Becker L50-17-M04: 4 min. IP rating — Becker L50-17-M04: IP44; A-OK AM45 Ultra-Quiet Battery Powered Awning Motor: IP44.

Sources

  1. ↑Becker-Antriebe product centre (product catalog)produktcenter.becker-antriebe.comSeries / product line: Serie M04Manufacturer-stated · Observed 2026-10-01 · Retrieved 2026-10-01 · Public web pageUsed for: 15841, 15843, 15861, 15837, 15863, 15849, 15864, 48514, 15851
  2. ↑A-OK Motor manufacturer site (product catalog)a-okmotor.comSeries / product line: AM45 Ultra-Quiet Battery Powered Awning MotorManufacturer-stated · Observed 2026-09-30 · Retrieved 2026-09-23 · Public web pageUsed for: 2682, 2677, 2674, 9835, 2678, 2679, 2672, 2673, 9836, 2675, 2680, 2681
  3. ↑Becker-Antriebe GmbH PDF cataloguebecker-antriebe.comRated voltage: Nennspannung: 230 V/AC / 50Hz [2050 110 106 0] (p. 14)Manufacturer-stated · Observed 2026-10-03 · Retrieved 2026-10-03 · Public web pageUsed for: 46204, 46206, 46205, 46203, 46202, 46199, 46200, 46207, 46208, 46201, 46209
  4. ↑https://produktcenter.becker-antriebe.com/Antriebe/Rollladenanwendungen/Antriebe-mit-mechanischer-Endabschaltung/L50-17-M04.htmlproduktcenter.becker-antriebe.comBecker L50-17-M04: tubular drive in produktcenter.becker-antriebe.com "Antriebe > Rollladenanwendungen" (https://produktcenter.becker-antriebe.com/Antriebe/Rollladenanwendungen/Antriebe-mit-mechanischer-Endabschaltung/L50-17-M04.html)Manufacturer-stated · Observed 2026-10-06 · Retrieved 2026-10-06 · Public web pageUsed for: 50676
  5. ↑https://www.a-okmotor.com/product/details_497_1256.htmla-okmotor.comA-OK AM45 Ultra-Quiet Battery Powered Awning Motor (AM45C-50/6-ES-E): a-okmotor.com Products > Tubular Motor (https://www.a-okmotor.com/product/details_497_1256.html); vendor application scenarios: straight-arm/crank-arm awning, zipper vertical sunshade, vertical awningManufacturer-stated · Observed 2026-10-06 · Retrieved 2026-10-06 · Public web pageUsed for: 50601, 50602