A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor vs A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor
Rated power input — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: 45 W [1; 2026-09-30]; A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: 115 W [1; 2026-10-02].
Rated current — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: 2 A [1; 2026-09-30]; A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: 0.5 A [1; 2026-10-02].
Rated speed — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: 20 rpm [1; 2026-09-30]; A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: 28 rpm [1; 2026-09-30].
Last verified: 2026-10-02
When to choose A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor
- For the stated supply type: AC mains [1; 2026-09-30].
- For a rated torque of 6 Nm [1; 2026-09-30].
- For a rated speed of 20 rpm [1; 2026-09-30].
- For the stated control protocol: Proprietary RF [1; 2026-09-30].
When to choose A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor
- For a supply rated 230 V [1; 2026-09-30].
- For the stated supply type: AC mains [1; 2026-10-02].
- For a rated torque of 6 Nm [1; 2026-10-02].
- For a rated speed of 28 rpm [1; 2026-09-30].
Verifiable indicators
Short-time duty (S2) — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: Not published. A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: Not published.
Rated life — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: Not published. A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: Not published.
Thermal protection — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: Not published. A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: Not published.
IP rating — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: IP64 [1; 2026-09-30]; A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: IP44 [1; 2026-10-02].
| Property | A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular MotorA-OKAM35-6/20-MEL-P-H | A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular MotorA-OKAM35-6/28-MEL-ZG |
|---|---|---|
| Series & variant axes | ||
| Series | AM35 | AM35 |
| Torque | 6 Nm | 6 Nm |
| Rated speedDiffers: 20 rpm vs 28 rpm | 20 rpm | 28 rpm |
| Electrical | ||
| Rated voltage | Not published | 230 V [1; 2026-09-30] |
| Power supply type | AC mains [1; 2026-09-30] | AC mains [1; 2026-10-02] |
| Supply rating (as stated) | 100-24V AC [1; 2026-09-30] | Not published |
| Rated power inputDiffers: 45 W [1; 2026-09-30] vs 115 W [1; 2026-10-02] | 45 W [1; 2026-09-30] | 115 W [1; 2026-10-02] |
| Rated currentDiffers: 2 A [1; 2026-09-30] vs 0.5 A [1; 2026-10-02] | 2 A [1; 2026-09-30] | 0.5 A [1; 2026-10-02] |
| Drive performance | ||
| Rated torque | 6 Nm [1; 2026-09-30] | 6 Nm [1; 2026-10-02] |
| Rated speedDiffers: 20 rpm [1; 2026-09-30] vs 28 rpm [1; 2026-09-30] | 20 rpm [1; 2026-09-30] | 28 rpm [1; 2026-09-30] |
| Limits & protection | ||
| Limit setting | Electronic [1; 2026-09-30] | Electronic [1; 2026-09-30] |
| Control & communication | ||
| Control protocol | Proprietary RF [1; 2026-09-30] | Proprietary RF [1; 2026-10-02] |
| Radio frequency | 433 MHz [1; 2026-10-01] | 433 MHz [1; 2026-10-01], 433.92 MHz [1; 2026-10-01] |
| Environment & protection | ||
| IP ratingDiffers: IP64 [1; 2026-09-30] vs IP44 [1; 2026-10-02] | IP64 [1; 2026-09-30]Highest stated | IP44 [1; 2026-10-02] |
| Appearance | ||
| Colour / finish | yellow [1; 2026-10-01] | Not published |
| View all 9 variants | ||
| Documents | Request datasheet | Request datasheet |
Same-series variants
| Variant axis | A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor | A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor |
|---|---|---|
| Rated speed | 20 rpm [A-OK Motor manufacturer site (product catalog); 2026-09-30] | 28 rpm [A-OK Motor manufacturer site (product catalog); 2026-09-30] |
Questions and answers
- What supply voltage and frequency does each use?
- Rated voltage — A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: 230 V. Power supply type — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: AC mains; A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: AC mains.
- What torque and speed is each rated for?
- Rated torque — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: 6 Nm; A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: 6 Nm. Rated speed — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: 20 rpm; A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: 28 rpm.
- What protocols and control options does each support?
- Limit setting — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: Electronic; A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: Electronic. Control protocol — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: Proprietary RF; A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: Proprietary RF.
- Which durability indicators does each publish?
- OpenAxia does not rate reliability; the published indicators are: IP rating — A-OK AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular Motor: IP64; A-OK AM35 AC Input Zero Gap Electronic limit Radio Tubular Motor: IP44.
Sources
- ↑A-OK Motor manufacturer site (product catalog)a-okmotor.comSeries / product line: AM35 AC Input Perfect Alignment Electronic Limit Radio Tubular MotorUsed for: 2986, 45783, 44709, 2979, 45784, 2978, 2982, 45785, 2983, 45786, 2976, 45787, 2977, 44708, 2985, 3027, 2984, 45788, 9875, 44710, 9879, 2980, 45789, 9874