A-OK AM25 AC Input Electronic Limit DC Tubular Motor vs Somfy Roll Up 28 · 1.1 Nm · 20 rpm
Rated torque — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: 1.2 Nm [1; 2026-09-30]; Somfy Roll Up 28 · 1.1 Nm [2; 2026-10-06] · 20 rpm: 1.1 Nm.
Rated speed — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: 25 rpm [1; 2026-09-30]; Somfy Roll Up 28 · 1.1 Nm · 20 rpm [2; 2026-10-06]: 20 rpm.
Radio frequency — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: 433.92 MHz [1; 2026-10-01]; Somfy Roll Up 28 · 1.1 Nm · 20 rpm: 433.42 MHz [2; 2026-10-06].
Last verified: 2026-10-06
When to choose A-OK AM25 AC Input Electronic Limit DC Tubular Motor
- For the stated supply type: AC mains [1; 2026-09-30], DC [1; 2026-09-30].
- For a rated torque of 1.2 Nm [1; 2026-09-30].
- For a rated speed of 25 rpm [1; 2026-09-30].
- For the stated control protocol: Proprietary RF [1; 2026-09-30], RS-485 [1; 2026-09-30].
When to choose Somfy Roll Up 28 · 1.1 Nm · 20 rpm
- For a supply rated 12 V [2; 2026-10-06].
- For the stated supply type: Battery [2; 2026-10-06], DC [2; 2026-10-06].
- For a rated torque of 1.1 Nm [2; 2026-10-06].
- For a rated speed of 20 rpm [2; 2026-10-06].
Verifiable indicators
Short-time duty (S2) — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: Not published. Somfy Roll Up 28 · 1.1 Nm · 20 rpm: Not published.
Rated life — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: Not published. Somfy Roll Up 28 · 1.1 Nm · 20 rpm: Not published.
Thermal protection — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: Not published. Somfy Roll Up 28 · 1.1 Nm · 20 rpm: Not published.
IP rating — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: IP44 [1; 2026-09-30]; Somfy Roll Up 28 · 1.1 Nm · 20 rpm: IP20 [2; 2026-10-06].
| Property | A-OK AM25 AC Input Electronic Limit DC Tubular MotorA-OKAM25-1.2/25-MEL-P | Somfy Roll Up 28 · 1.1 Nm · 20 rpmSomfy1240291 |
|---|---|---|
| Series & variant axes | ||
| SeriesDiffers: AM25 vs Roll Up 28 | AM25 | Roll Up 28 |
| Identity & lineage | ||
| Series / product line | AM25 [1; 2026-09-30] | Not published |
| Electrical | ||
| Rated voltage | Not published | 12 V [2; 2026-10-06] |
| Supply voltage (min) | 100 V [1; 2026-09-30] | Not published |
| Supply voltage (max) | 240 V [1; 2026-09-30] | Not published |
| Power supply type | AC mains [1; 2026-09-30], DC [1; 2026-09-30] | Battery [2; 2026-10-06], DC [2; 2026-10-06] |
| Supply rating (as stated) | 100-240V [1; 2026-09-30] | Not published |
| Rated power input | 1.2 W [1; 2026-09-30] | Not published |
| Drive performance | ||
| Rated torqueDiffers: 1.2 Nm [1; 2026-09-30] vs 1.1 Nm [2; 2026-10-06] | 1.2 Nm [1; 2026-09-30] | 1.1 Nm [2; 2026-10-06] |
| Rated speedDiffers: 25 rpm [1; 2026-09-30] vs 20 rpm [2; 2026-10-06] | 25 rpm [1; 2026-09-30] | 20 rpm [2; 2026-10-06] |
| Limits & protection | ||
| Limit setting | Electronic [1; 2026-09-30] | Electronic [2; 2026-10-06] |
| Control & communication | ||
| Control protocolDiffers: Proprietary RF, RS-485 [1; 2026-09-30] [1; 2026-09-30] vs RTS [2; 2026-10-06] | Proprietary RF [1; 2026-09-30], RS-485 [1; 2026-09-30] | RTS [2; 2026-10-06] |
| Radio frequencyDiffers: 433.92 MHz [1; 2026-10-01] vs 433.42 MHz [2; 2026-10-06] | 433.92 MHz [1; 2026-10-01] | 433.42 MHz [2; 2026-10-06] |
| Radio range | Not published | 200 m [3; 2026-10-05] |
| Battery & charging | ||
| Battery (as stated) | Not applicable | 12V 2600 mAh (built-in Lithium-ion) [2; 2026-10-06] |
| Battery capacity | Not applicable | 2,600 mAh [2; 2026-10-06] |
| Environment & protection | ||
| IP ratingDiffers: IP44 [1; 2026-09-30] vs IP20 [2; 2026-10-06] | IP44 [1; 2026-09-30]Highest stated | IP20 [2; 2026-10-06] |
| Operating temp. (min) | Not published | 0 °C [2; 2026-10-06] |
| Operating temp. (max) | Not published | 60 °C [2; 2026-10-06] |
| Noise level | Not published | 56 dB(A) [3; 2026-10-05] |
| Compliance & declarations | ||
| Marks stated by vendor | Not published | CE [3; 2026-10-05] |
| Documents | Request datasheet | Request datasheet |
Series
Questions and answers
- What supply voltage and frequency does each use?
- Rated voltage — Somfy Roll Up 28 · 1.1 Nm · 20 rpm: 12 V. Power supply type — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: AC mains, DC; Somfy Roll Up 28 · 1.1 Nm · 20 rpm: Battery, DC.
- What torque and speed is each rated for?
- Rated torque — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: 1.2 Nm; Somfy Roll Up 28 · 1.1 Nm · 20 rpm: 1.1 Nm. Rated speed — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: 25 rpm; Somfy Roll Up 28 · 1.1 Nm · 20 rpm: 20 rpm.
- What protocols and control options does each support?
- Limit setting — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: Electronic; Somfy Roll Up 28 · 1.1 Nm · 20 rpm: Electronic. Control protocol — A-OK AM25 AC Input Electronic Limit DC Tubular Motor: Proprietary RF, RS-485; Somfy Roll Up 28 · 1.1 Nm · 20 rpm: RTS.
- What certifications are on record for each?
- Marks stated by vendor — Somfy Roll Up 28 · 1.1 Nm · 20 rpm: CE.
Sources
- ↑A-OK Motor manufacturer site (product catalog)a-okmotor.comSeries / product line: AM25 AC Input Electronic Limit DC Tubular MotorUsed for: 2731, 7127, 7129, 2724, 2723, 2722, 2727, 2720, 2721, 2730, 2728, 2729, 9847, 2725
- ↑Somfy PDF catalogueservice.somfy.comRated voltage: Voltage Supply: 12V DC [1240291] (p. 6)Used for: 50458, 50460, 50459, 50465, 50466, 50462, 50467, 50468, 50469, 50470, 50461, 50463, 50464
- ↑Somfy Systems (North America) manufacturer site (product catalog)somfysystems.comRadio range: Range in open field 656.2 ftUsed for: 49827, 49829, 49830